G3 Switch 0B
FUNCTION
COMMENTS
0
Protocol requirements:
Europe
0: Disabled 1: Enabled
Program these bit switches manually to match local
requirements.
1
Protocol requirements:
Spain
0: Disabled 1: Enabled
2
Protocol requirements:
Germany
0: Disabled 1: Enabled
3
Protocol requirements:
France
0: Disabled 1: Enabled
4
PTT requirements: Germany
0: Disabled 1: Enabled
5
PTT requirements: France
0: Disabled 1: Enabled
6-7
Not used
Do not change the settings.
G3 Switch 0C
FUNCTION
COMMENTS
0
1
Pulse dialing method
Bit 1 Bit 0 Setting
0 0 Normal (P=N)
0 1 Oslo (P=10 - N)
1 0 Sweden (N+1)
1 1 Not used
P = Number of pulses sent out, N = Number dialed.
2-7
Not used
Do not change the settings.
G3 Switch 0D - Not used (do not change the settings)
G3 Switch 0E - Not used (do not change the settings)
G3 Switch 0F - Not used (do not change the settings)
Ser
v
ic
e T
a
b
les
June 10th, 1997
SERVICE TABLES AND PROCEDURES
BIT SWITCHES
4-39
Summary of Contents for Aficio FX10
Page 1: ...LFO AFICIO FX10 SERVICE MANUAL June 10th 1997 Subject to change...
Page 244: ...0RGHO 2 XURSH UDQFH VLD...
Page 246: ...2 19 1 EXTERIOR 1...
Page 248: ...4 28 30 29 2 EXTERIOR 2...
Page 250: ...6 3 CASSETTE...
Page 252: ...8 4 ADF UNIT 1...
Page 254: ...10 5 ADF UNIT 2...
Page 256: ...12 6 SCANNER 1...
Page 258: ...14 7 SCANNER 2...
Page 260: ...16 8 LASERUNIT...
Page 262: ...18 9 PAPER FEED SECTION...
Page 264: ...20 10 DEVELOPMENT UNIT...
Page 266: ...22 39 40 41 11 FUSING UNIT...
Page 268: ...24 12 PAPER EXIT SECTION 1...
Page 270: ...26 13 FRAME AND ELECTRICAL SECTION 1...
Page 272: ...28 26 14 FRAME AND ELECTRICAL SECTION 2...
Page 274: ...30 15 OPTION CASSETTE...
Page 276: ...34 PARTS INDEX...