Richter PSG/F series Operating Manual Download Page 5

Series PSG/F, TSG/F

 

Page 5 

 

9540-050-en

 

Revision   10 

TM 8361

 

Edition   10/2011 

1.3  Pressure/temperature diagram 

According to AD 2000 

 

According to ASME B 16.42 

 

When  used  in  the  area  of  application  of  ASME, 
the low temperature of ASTM A395 is limited to -20°F 
(-29°C).

 

When  used  in  the  minus  temperature  range, 
the  regulations  applicable  in  the  country  in 
question must be observed. 
 

2

Notes on safety 

This 

operating 

manual 

contains 

fundamental 

information which is to be observed during installation, 
operation and maintenance.  

It  must  therefore  be  read  before  installation  and 
commissioning! 

For  valves  which  are  used  in  potentially  explosive 
areas, see 

Section 3

.

Installation  and  operation  are  to  be  performed  by 
qualified staff. 

The area of responsibility, authority and supervision of 
the staff must be regulated by the customer. 

 

General hazard symbol! 

People may be put at risk. 
 

Safety  symbol!

  The  ball  valve  and  its 

function  may  be  put  at  risk  if  this  safety 
symbol is not observed. 
 

It  is  imperative  to  observe  warnings  and  signs 
attached  directly  to  the  ball  valve  and  they  are  to  be 
kept fully legible.

 

Non-observance of the notes on safety may result 
in the loss of any and all claims for damages. 

For  example,  non-observance  may  involve  the 
following hazards: 

Failure of important functions of the valve/plant. 

Risk  to  people  from  electric,  mechanical  and 
chemical effects. 

Risk  to  the  environment  through  leaks  of 
hazardous substances. 

 

Summary of Contents for PSG/F series

Page 1: ...trictly observed before transport installation operation and maintenance Subject to change without notice Reproduction is generally permitted with indication of the source Richter Chemie Technik GmbH...

Page 2: ...osal 7 5 1 Storage 8 5 2 Return consignments 8 5 3 Disposal 8 6 Installation 8 6 1 Flange caps and gaskets 8 6 2 Direction of flow and installation position 8 6 3 Grounding 8 6 4 Test pressure 8 7 Ope...

Page 3: ...iagram in Section 1 3 Operating pressure DN 25 100 from vacuum to max 16 bar DN 150 200 from vacuum to max 10 bar See pressure temperature diagram in Section 1 3 Strainer size PSG F DN 25 40 50 65 80...

Page 4: ...O DIN drilled to ASME Class 150 Flange nom size Screws Tightening torque mm inch ASME Nm in lbs 25 1 4 x 8 70 40 1 4 x 15 135 50 2 4 x J 25 220 65 2 4 x J 30 265 80 3 4 x J 45 400 100 4 8 x J 35 310 1...

Page 5: ...tentially explosive areas see Section 3 Installation and operation are to be performed by qualified staff The area of responsibility authority and supervision of the staff must be regulated by the cus...

Page 6: ...2 1 of this operating manual The operation limits specified on the identification plate and in the pressure temperature diagram must under no circumstances be exceeded 3 Safety notes for applications...

Page 7: ...the temperature classes prescribed in the Annex are observed To achieve safe and reliable operation it must be ensured in inspections at regular intervals that the valve is properly serviced and kept...

Page 8: ...s Neutralise any medium residues in the valve Separate valve materials plastics metals etc and dispose of them in accordance with the local regulations 6 Installation Examine valve for in transit dama...

Page 9: ...sidual medium may still be found in the valve After dismantling immediately protect the valve flanges against mechanical damage with flange caps See also Section 6 1 8 Malfunctions Flange connection v...

Page 10: ...10 Drawing 10 1 Legend 100 body 106 cover 114 pane 408 seal 902 1 stud screw 920 1 hex nut 936 1 toothed lock washer Option Flexicord strip 981 1 Flexicord strip Option double glass pane 417 U seal 10...

Page 11: ...Series PSG F TSG F Page 11 9540 050 en Revision 10 TM 8361 Edition 10 2011 10 3 Sectional drawing PSG F 10 4 Sectional drawing TSG F Option Option...

Page 12: ...mm mm mm mm mm mm L 160 200 230 290 310 350 480 A 85 110 120 175 190 210 250 a 48 65 80 80 100 125 137 B1 ca 135 ca 155 ca 185 ca 194 ca 246 ca 294 ca 374 B2 ca 158 ca 182 ca 218 ca 289 ca 347 Option...

Page 13: ...sional drawing TSG F DN 25 50 80 mm mm mm D 115 165 200 L 160 230 310 a 48 80 100 b 80 115 155 B1 ca 135 ca 185 ca 246 B2 ca 158 ca 218 ca 289 Option Double glass panes Flange connecting dimensions DI...

Page 14: ...echnische Spezifikation AD 2000 Applied Technical Specification berwachungsverfahren 97 23 EG Surveillance Procedure Zertifizierungsstelle f r Druckger te der T V Nord Systems GmbH Co KG Notified Body...

Page 15: ......

Page 16: ...mination of the pumps valves and component sent in for repair On the basis of this information for the contractor is it possible to meet the necessary preventive action during the execution of the rep...

Page 17: ...logical 2 and with which cleaning method radioactive 3 1 if no then forward to D other pollutant 2 Aggregates which are contaminated with microbiological or explosive substances are only accepted with...

Page 18: ...IOSTOFFV the procedures for the prevention of accidents as well as regulations to environmental protection e g the Waste Management Law AbfG and the Water Resources Act WHG An inspection repair of Ric...

Reviews: