Richter PSG/F series Operating Manual Download Page 14

Richter Chemie-Technik GmbH 
Otto-Schott-Straße 2 
D-47906 Kempen 
www.richter-ct.com 

Erstellt/Compiled: 

CRM/GK 

am/on: 14.01.2011 

Seite/Page :  1 

QM-Nr.: 0905-40-1047/4-00-de-en 

Genehmigt/Approved:  CRQ/AL 

am/on: 14.01.2011 

von/of : 

TM 8107 

A Unit of IDEX Corporation 

 

 

Konformitätserklärung  

nach EN ISO//IEC 17050

 

Declaration of Conformity  

according to EN ISO//IEC 17050

 

 

 
Produkt 

Kunststoffausgekleidete Schaugläser und Schmutzfänger 

Product 

Plastic lined sight glasses and strainers 

 
Bauart 

Schauglas, Schmutzfänger  

Design 

Sight glass, strainer  

 
Baureihe 

PSG, TSG, GS, GSO, SGS 

Series

 

 

 
Nennweite 

DN 15 bis DN 200, 

½

“ bis 8“ 

Size 

DN 15 to DN 200, 

½

“ 

to 8“ 

 
Seriennummer 

ab/

from

  29.12.2009 

Series number 

 
EU-Richtlinie 

97/23/EG Druckgeräterichtlinie 

EU-Directive

 

97/23/EC

 

Pressure Equipment

 

Directive

 

 
Angewandte 

DIN EN ISO 12100-2 

Technische Spezifikation 

AD 2000 

Applied Technical Specification 

 

 
Überwachungsverfahren 

97/23/EG 

Surveillance Procedure 

Zertifizierungsstelle für Druckgeräte

 

 

der TÜV Nord Systems GmbH & Co. KG

 

 

Notified Body 0045 

 
Konformitätsbewertungs- 

Modul H 

verfahren 97/23/EG 

 

Conformity assessment  

 

procedure 97/23/EC

 

 

 

Kennzeichnung 

97/23/EG 

1)   

≥ DN 32,  ≥ 1“  

Marking

 

97/23/EC 

1)  

 

≥ DN 32,  ≥ 1“ 

 

 
 
Das  Unternehmen  Richter  Chemie-Technik  GmbH  bescheinigt  hiermit,  dass  die  o.a.  Baureihen  die 
grundsätzlichen Anforderungen der aufgeführten Richtlinien und Normen erfüllt. 

Richter  Chemie-Technik  GmbH  confirms  that  the  basic  requirements  of  the  above  specified  directives  and 
standards have been fulfilled. 

 
 

1)

  

Für nicht aufgeführte Nennweiten ist eine Kennzeichnung nicht zulässig. 

 

For sizes not listed a marking is not permissible. 

 
 
 
Kempen, 14.01.2011 
 
 
 
 

 

  ________________________________   

  _________________________________  

 
G. Kleining 

 

A. Linges 

Leiter Forschung & Entwicklung 

 

Leiter Qualitätsmanagement 

Manager Research & Development  

Quality Manager 

0045 

Summary of Contents for PSG/F series

Page 1: ...trictly observed before transport installation operation and maintenance Subject to change without notice Reproduction is generally permitted with indication of the source Richter Chemie Technik GmbH...

Page 2: ...osal 7 5 1 Storage 8 5 2 Return consignments 8 5 3 Disposal 8 6 Installation 8 6 1 Flange caps and gaskets 8 6 2 Direction of flow and installation position 8 6 3 Grounding 8 6 4 Test pressure 8 7 Ope...

Page 3: ...iagram in Section 1 3 Operating pressure DN 25 100 from vacuum to max 16 bar DN 150 200 from vacuum to max 10 bar See pressure temperature diagram in Section 1 3 Strainer size PSG F DN 25 40 50 65 80...

Page 4: ...O DIN drilled to ASME Class 150 Flange nom size Screws Tightening torque mm inch ASME Nm in lbs 25 1 4 x 8 70 40 1 4 x 15 135 50 2 4 x J 25 220 65 2 4 x J 30 265 80 3 4 x J 45 400 100 4 8 x J 35 310 1...

Page 5: ...tentially explosive areas see Section 3 Installation and operation are to be performed by qualified staff The area of responsibility authority and supervision of the staff must be regulated by the cus...

Page 6: ...2 1 of this operating manual The operation limits specified on the identification plate and in the pressure temperature diagram must under no circumstances be exceeded 3 Safety notes for applications...

Page 7: ...the temperature classes prescribed in the Annex are observed To achieve safe and reliable operation it must be ensured in inspections at regular intervals that the valve is properly serviced and kept...

Page 8: ...s Neutralise any medium residues in the valve Separate valve materials plastics metals etc and dispose of them in accordance with the local regulations 6 Installation Examine valve for in transit dama...

Page 9: ...sidual medium may still be found in the valve After dismantling immediately protect the valve flanges against mechanical damage with flange caps See also Section 6 1 8 Malfunctions Flange connection v...

Page 10: ...10 Drawing 10 1 Legend 100 body 106 cover 114 pane 408 seal 902 1 stud screw 920 1 hex nut 936 1 toothed lock washer Option Flexicord strip 981 1 Flexicord strip Option double glass pane 417 U seal 10...

Page 11: ...Series PSG F TSG F Page 11 9540 050 en Revision 10 TM 8361 Edition 10 2011 10 3 Sectional drawing PSG F 10 4 Sectional drawing TSG F Option Option...

Page 12: ...mm mm mm mm mm mm L 160 200 230 290 310 350 480 A 85 110 120 175 190 210 250 a 48 65 80 80 100 125 137 B1 ca 135 ca 155 ca 185 ca 194 ca 246 ca 294 ca 374 B2 ca 158 ca 182 ca 218 ca 289 ca 347 Option...

Page 13: ...sional drawing TSG F DN 25 50 80 mm mm mm D 115 165 200 L 160 230 310 a 48 80 100 b 80 115 155 B1 ca 135 ca 185 ca 246 B2 ca 158 ca 218 ca 289 Option Double glass panes Flange connecting dimensions DI...

Page 14: ...echnische Spezifikation AD 2000 Applied Technical Specification berwachungsverfahren 97 23 EG Surveillance Procedure Zertifizierungsstelle f r Druckger te der T V Nord Systems GmbH Co KG Notified Body...

Page 15: ......

Page 16: ...mination of the pumps valves and component sent in for repair On the basis of this information for the contractor is it possible to meet the necessary preventive action during the execution of the rep...

Page 17: ...logical 2 and with which cleaning method radioactive 3 1 if no then forward to D other pollutant 2 Aggregates which are contaminated with microbiological or explosive substances are only accepted with...

Page 18: ...IOSTOFFV the procedures for the prevention of accidents as well as regulations to environmental protection e g the Waste Management Law AbfG and the Water Resources Act WHG An inspection repair of Ric...

Reviews: