![Rice Lake TA Plus 124 Operation Manual Download Page 43](http://html1.mh-extra.com/html/rice-lake/ta-plus-124/ta-plus-124_operation-manual_1454254043.webp)
©
Rice Lake Weighing Systems
●
All Rights Reserved
37
Configuration
5.4 User Information
Describes setting items related to the comparator function and preset tare weight.
Figure 5-6. User Information Menu
Table 5-6. User Information Menu
5.4.1 Preset Tare Mode
A preset tare can be selected prior to weighing. See
INPUT VALUE
PRESET 3
31 PT MODE
3 USER INFO
33 COMPARE WEIGHT
32 PT INPUT
1
2
3
4
OFF
5
INPUT VALUE
PRESET 1
INPUT VALUE
PRESET 2
INPUT VALUE
PRESET 4
INPUT VALUE
PRESET 5
INPUT VALUE
WEIGHT LOW
INPUT VALUE
WEIGHT HIGH
INPUT VALUE
WEIGHT REF
34 COMPARE PERCENT
INPUT VALUE
PERCENT LOW
INPUT VALUE
PERCENT HIGH
INPUT VALUE
PERCENT REF
35 COMPARE COUNT
INPUT VALUE
COUNT LOW
INPUT VALUE
COUNT HIGH
INPUT VALUE
COUNT REF
36 COMPARE MULT
INPUT VALUE
MULTIPLY LOW
INPUT VALUE
MULTIPLY HIGH
INPUT VALUE
MULTIPLY REF
Menu
Parameters
Description
31 PT MODE
Preset Tare Execution
Off
Invalid
Setting 1-5
Execute
32 PT INPUT
Preset tare weight setting
Preset 1-5
Setting value input
33 COMPARE WEIGHT Weight Comparator
Weight High
Setting value input
Weight Ref
Weight Low
34 COMPARE PERCENT % Comparator
Percent High
Setting value input
Percent Ref
Percent Low
35 COMPARE COUNT
Comparator Counting
Count High
Setting value input
Count Ref
Count Low
36 COMPARE MULT
Multiple Comparator
Multiply High
Setting value input
Multiply Ref
Multiply Low
Menu
Parameters
Description