Operation
© Rice Lake Weighing Systems
●
All Rights Reserved
49
Divisions And Units Measure Registry (40014)
This register contains the current settings of the divisions parameter (
) and the units of measure parameter (
).
Use this register together with the
registers to calculate the value displayed by the SCT20-MB.
Possible Commands To Send To The Command Register (40006)
Least significant byte
L Byte (Division)
Most significant byte
H Byte (Units of Measure)
Division
value
Divisor Decimals
Units of measure
value
Units of measure
description
Utilization of the Coefficient value
with the different units of
measure settings compared to
the gross weight detected
0
100
0
0
Kilograms
Does not intervene
1
50
0
1
Grams
Does not intervene
2
20
0
2
Tons
Does not intervene
3
10
0
3
Pounds
Does not intervene
4
5
0
4
Newton
Multiples
5
2
0
5
Litres
Divides
6
1
0
6
Bar
Multiples
7
0.5
1
7
Atmspheres
Multiples
8
0.2
1
8
Pieces
Divides
9
0.1
1
9
Newton Meter
Multiples
10
0.05
2
10
Kilogram Meter
Multiples
11
0.02
2
11
Other
Multiples
12
0.01
2
13
0.005
3
14
0.002
3
15
0.001
3
16
0.0005
4
17
0.0002
4
18
0.0001
4
Table 3-38. Divisions and Units of Measure (Analog Model)
Code
Descriptions
Code
Description
0
No command
17
Reserved
1
—
18
Reserved
2
—
19
—
3
—
20
—
4
—
21
Keypad lock
5
—
22
Keypad and display unlock
6
—
23
Keypad and display lock
7
NET display
24
8
SEMI-AUTOMATIC ZERO
99
Save data in EEPROM
9
GROSS display
100
Zero-setting for calibration
10
Reserved
101
Test weight storage for calibration
11
Reserved
—
12
Reserved
—
13
Reserved
—
14
Reserved
—
15
Reserved
—
16
Reserved
9999
Reset (reserved)
Table 3-39. Commands to Command Register (Analog Model)