Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
27
2.13.4 Default Scale
Operation must only be performed after contacting technical assistance
1. With power off, press and hold , then power on. Display shows
.
2. Press
,
is displayed.
3. Press ,
is displayed.
4. Press
,
is displayed.
5. Press and to enter
.
6. Press
,
is displayed.
7. Instrument will reboot.
By confirming the displayed program, the system variables are set to default values.
2.13.5 Program Selection - Reverse
Scale capacity is displayed when scale is empty. As weight is added display counts down.
1. With power off, press and hold , then power on.
is displayed.
2. Press
,
is displayed.
3. Press ,
is displayed.
4. Press
,
is displayed. Instrument will reboot.
2.13.6 Program Selection - Not Legal:
Scale approval state is preset for not-legal. For other options please contact Rice Lake Weighing Systems Technical Support:
: Not Legal for Trade.
: Legal for Trade (OIML)
: Legal for Trade, multi-interval (OIML)
1. With power off, press and hold , then power on.
is displayed.
2. Press
,
is displayed.
3. Press
,
is displayed.
4. Press
,
is displayed. The instrument will reboot.
Press to quit the program without introducing any changes and without deleting any of the set variables.
If necessary, a manual for the newly set program can be requested it from Rice Lake Weighing Systems Technical
Support.
2.13.7 Keypad Or Display Locking
1. Press immediately followed by and hold both down for about five seconds (this operation is also possible via
the MODBUS and ASCII protocols).
2. Press or until desired parameter is displayed. Press
.
Parameter
Description
no lock
keypad lock: if active, when key is pressed the message
is displayed.
Keypad and Display lock: if active, the keypad is locked and the display shows the instrument model (weight is
not displayed); by pressing a key the display shows
for three seconds.
Table 2-18. Keypad or Display Locking Parameters
IMPORTANT
Note
Note