Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
19
2.5 SCT-20 DeviceNet™ Settings
1. Press and hold
and .
is displayed.
2. Press or until
is displayed. Press
.
3. Press or until desired parameter is displayed. Press
.
4. Press or until desired value is displayed. Press
.
5. Press twice to exit set-up menu.
2.6 Analog Output
Figure 2-5. Analog Menu Structure
Parameter
Options
Description
*
Set instrument address in the DeviceNet™ network.
*
Set instrument address in the DeviceNet™ network.
* Indicates default value.
Table 2-9. DeviceNet Parameters
Parameter
Options
Description
Select the analog output type.
Select the mode to be tracked, gross or net. If the net function is not active, the analog output varies according to gross
weight.
--
Set the weight value for the minimum analog output value.
NOTE: Only set a value different from zero to limit the analog output range.
Example: for a full scale value of 10000 kg, a 4 mA signal at 5000 kg is required, and 20 mA at 10000 kg, in this case,
instead of zero, set 5000 kg.
--
Set the weight value for the maximum analog output value; it must correspond to the value set in the PLC program
(default: calibration full scale).
Example: if using a 4-20 mA output and in the PLC program a 20 mA = 8000 kg is desired, set the parameter to 8000
.
--
Analog output correction to zero: if necessary adjust the analog output, allowing the PLC to indicate 0. The sign ‘-‘ can be
set for the last digit on the left.
Example: for a 4-20 mA output and a minimum analog setting, the PLC or tester reads 4.1 mA. Set the parameter to 3.9 to
obtain 4.0 on the PLC or tester. See Analog Output Type Scale Corrections for additional information.
Table 2-10. Analog Menu Parameters