SCT-20 Series
38
Visit our website
Generic EtherNet/IP Module Setup
The configuration used when setting up a device with the generic module file.
Figure 3-2. Dual Port – Generic EtherNet/IP Module Setup
Generic EtherNet/IP module setup uses the same input data as EDS file setup. See
.
Possible Command To Send To The Command Register
To execute the same command twice consecutively, send command 0 between the first command and the following
one.
Output Data from SCT-20 EtherNet/IP (Read)
Addresses
Type
Header Information [4 bytes]
0x0000-0x0003
Double Integer
Gross Weight [4 byte]
0x0004-0x0007
Double Integer
Net Weight [4 byte]
0x0008-0x000B
Double Integer
Exchange Register [4 byte]
0x000C-0x000F
Double Integer
Status Register [2 byte]
0x0010-0x0011
Integer
Digital Inputs status [2 byte]
0x0012-0x0013
Integer
Digital Outputs status [2 byte]
0x0014-0x0015
Integer
Table 3-21. Generic Module Output Data – Dual Port Interface (EtherNet/IP)
Code
Description
Code
Description
0
No command
7
Semi-Automatic Tare enabling (net weight displaying)
8
Semi-Automatic Zero
9
Semi-Automatic Tare disabling (gross weight displaying)
20
21
Keypad lock
22
Keypad and display unlock
23
Keypad and display lock
86
87
Preset Tare reading*
88
Preset Tare writing*
89
90
Setpoint 1 reading*
91
Setpoint 2 reading*
92
Setpoint 3 reading*
93
Setpoint 1 writing*
94
Setpoint 2 writing*
95
Setpoint 3 writing*
98
99
Save data in EEPROM
100
Tare Weight Zero Setting for calibration
101
Sample weight storage for calibration
102
Sample Weight reading*
103
Sample Weight writing*
130
Preset Tare enabling
131
Table 3-22. Commands to Command Register (EtherNet/IP)
Note
Note