![Rice Lake Measurement Systems International MSI9750A Operator'S Manual Download Page 62](http://html1.mh-extra.com/html/rice-lake/measurement-systems-international-msi9750a/measurement-systems-international-msi9750a_operators-manual_1454015062.webp)
Page 62 MSI-9750A RF Remote Indicator • User Guide
9750A
HANDHELD RF REMOTE INDICATOR for
C
ELL
S
CALE
®
Output Time
@T
1=HH:MM
AM/PM
2=HH:MM:SS
AM/PM
3=HH:MM
4=HH:MM:SS
@T1
@T2
@T3
@T4
04:22*PM
04:22:35*PM
16:22
16:22:35
Output Current units
@U
None
@U
LB**
pounds
KG**
kilograms
TON*
Short Tons
MTON*
Metric Tons
OZ**
ounces
G***
grams
DAN*
dekanewtons
Output Name
@N
1=Current Channel Name
2=Current ID Name
3=Current Set Point
4=Scan List Position
5=Channel Number
6=Fkey Label Print Str1
7=Fkey Label Print Str2
@N1
@N2
@N3
@N4
@N5
@N6
@N7
SCALE PLATFORM 2
APPLES**
always 8 characters
WARNING1**
always 8 characters
SC 21
always 5 characters
CH 1-1
always 6 characters
OPERATOR
always 8 characters
CUSTOMER
always 8 characters
Output Set Point Parameters
@S
01-32
@S01
Outputs ~1000 bytes of formatted data describ-
ing all set point parameters
Output Comm Port Data String @P
1-5
@P1
Output Comm Port 1’s data string
This command is used to embed print strings
from one comm port to another. Do not embed
a print string inside itself.
Output Weight (Value only)
@V
1=current weight
2=gross
3=net
4=tare
5=total
6=# of totals
7= total, # of totals
8=reserved
9=last totaled weight
%=%of capacity
@V1
@V2
@V3
@V4
@V5
@V6
@V7
@V9
@V%
**20.002
Length: 8, fi xed. Leading zeros suppressed
**205.08
Length: 8, fi xed. Leading zeros suppressed
*1188.50
Length: 8, fi xed. Leading zeros suppressed
****5000
Length: 8, fi xed. Leading zeros suppressed
*432534.85
Length: 10, fi xed. Leading zeros suppressed
12345
Length: 5, fi xed. Leading zeros suppressed
*432534.85,12345
Length: 16, fi xed. Leading zeros suppressed
**200.05
Length: 8, fi xed. Leading zeros suppressed
***31.04
Length: 8, fi xed. Leading zeros suppressed
Output a scale mode
@M
@M1
@M2
@M3
@M4
@M5
@M6
@M7
@M9
@M%
GROSS* or NET
GROSS*
NET***
TARE**
TOTAL*
T*CNT*
TOTAL*T*CNT
GROSS+ or NET+
%G-CAP
1=
Current
2=Gross
3=Net
4=Tare
5=Total
6=# Totals
7=Total, #Ttls
8=
reserved
9=Last Total
%
Description
Cmd
Command Suffi x
Input
examples
Output examples &
comments
*= a space or place holder
Output ID String
@L
1=ID String 1
2=ID String 2
@L1
@L2
String 1 from the current ID. ≤20 Bytes.
String 2 from the current ID. ≤20 Bytes.
Print Modem ID
@I
1
@I1
xxx where x is the modem ID from 1-254
Not Applicable on 9750A