Configuration
21
3.2
Menu Structures and Parameter Descriptions
The following sections provide graphic representations of the
IQ plus 210
menu structures. In the actual menu
structure, the values under each parameter are arranged horizontally. To save page space, menu choices are shown
in vertical columns. The factory default setting appears at the top of each column.
Most menu diagrams are accompanied by a table that describes all parameters and parameter values associated
with that menu. Default parameter values are shown in bold type.
3.2.1
Configuration Menu
Figure 3-6. Configuration Menu
CONFIG Menu
Parameter
Choices
Description
Level 2 submenus
GRADS
5000
number
Graduations. Specifies the number of full scale graduations. The value entered must be in
the range 1–10 000 and should be consistent with legal requirements and environmental
limits on system resolution.
To calculate GRADS, use the formula, GRADS =
Capacity
/
Display Divisions
.
Display divisions for primary and secondary units are specified on the FORMAT menu.
ZTRKBN
OFF
0.5D
1D
3D
Zero track band. Automatically zeroes the scale when within the range specified, as long as
the input is within the configured zero range (ZRANGE parameter). Selections are ± display
divisions. Maximum legal value varies depending on local regulations.
ZRANGE
100%
1.9%
Zero range. Selects the range within which the scale can be zeroed. The 1.9% selection is ±
1.9% around the calibrated zero point, for a total range of 3.8%. Indicator must be at
standstill to zero the scale. Use 1.9% for legal-for-trade applications.
MOTBAN
1D
2D
3D
5D
10D
20D
OFF
Motion band. Sets the level, in display divisions, at which scale motion is detected. If motion
is not detected for 1 second or more, the standstill symbol lights. Some operations,
including print, tare, and zero, require the scale to be at standstill. Maximum legal value
varies depending on local regulations.
If OFF is selected, ZTRKBN should also be set to OFF.
OVRLOA
FS+2%
FS+1D
FS+9D
FS
Overload. Determines the point at which the display blanks and an out-of-range error
message is displayed. Maximum legal value varies depending on local regulations.
Table 3-2. Configuration Menu Parameters
XXXXXXX
XXXXXXX
GRADS
5000
OFF
1D
0.5D
3D
ZTRKBN
ZRANGE
100%
1.9%
OFF
2D
1D
3D
MOTBAN
10D
5D
20D
FS+2%
FS+9D
FS+1D
FS
OVRLOA
1
8
4
16
FILTER
8RT
4RT
16RT
number
VERS
DEFLT
DIG IN
SERIAL
CALIBR
CONFIG
FORMAT
2