background image

4

BenchPro Series Operation Manual

1.3.3

Keys and Symbols

For reference

 

only - Capacity

 

marking

 

changes with

 

model.

Figure 1-4. BenchPro Series Operator Display

Note

Additional capacity labels are provided with each unit. If using a scale in the applicable lb/oz mode or multi-
range kg mode, install the correct label over the existing capacity markings. See 

Figure 1-5 on page 5

.

Table 1-2. Key Functions

Key

Normal Operating Function

User and Configuration Mode Function

Quick press to turn the unit on
Perform a zero function
Press and hold for three seconds to turn the unit off

N/A

Toggle between configured weight units

Enter or accept the value selected 

Perform a tare function (if enabled)

Scroll left

Quick press to enter the user menu and configure 

















 and 



 

parameters of the scale. See 

Section 3.1 on page 9

Scroll right

Table 1-3. Annunciator Functions

LCD Annunciator

Description

0

Stable zero — indicates the scale is at a stable zero weight value

G/B

Gross/Brutto — indicates the scale is in gross mode.

N

Net — indicates a Tare condition and the net weight is displayed

W1, W2, W3

Weight range — indicates the weight range mode the scale is displaying

lb, lb:oz, oz, kg, g

Units of Measure — indicates the unit of measure the scale is displaying 

power

Power LED — indicates scale is plugged into an AC outlet, batteries are charged, USB power is pro-
vided through the USB cable

Summary of Contents for BenchPro Series

Page 1: ...BenchPro Series Version 1 Operation Manual PN 180557 Rev B...

Page 2: ...marks of their respective companies All information contained within this publication is to the best of our knowledge complete and accurate at the time of publication Rice Lake Weighing Systems reserv...

Page 3: ...rator Display 3 1 3 3 Keys and Symbols 4 1 4 Capacity by Model Type 5 1 5 Operation 6 1 5 1 Initial Power Up 6 1 5 2 Weigh Mode 6 1 5 3 Tare 6 2 0 Setup 7 2 1 Unpacking the Scale 7 2 2 Scale Setup 7 2...

Page 4: ...d topics at no cost Visit www ricelake com webinars 6 0 Maintenance and Troubleshooting 34 6 1 Troubleshooting 34 6 2 Load Cell Wiring 34 6 3 Replacement Parts 35 7 0 Specifications 36 Rice Lake conti...

Page 5: ...tially hazardous situation that if not avoided could result in minor or moderate injury Important Indicates information about procedures that if not observed could result in damage to equipment or cor...

Page 6: ...enchPro Series Options 1 2 3 Display Mounting Options Each model includes a mounting bracket The bracket attaches to the base plate or can be mounted on the wall The operator display attaches to the m...

Page 7: ...play 14 2 361 mm 14 0 356 mm 14 5 368 mm 14 6 371 mm 2 7 69 mm 2 8 72 mm Figure 1 2 Dimensions Scale Mount Operator Display 1 3 2 Optional Column Post Mount Operator Display 14 5 368 mm 14 5 368 mm 14...

Page 8: ...Toggle between configured weight units Enter or accept the value selected Perform a tare function if enabled Scroll left Quick press to enter the user menu and configure and parameters of the scale S...

Page 9: ...platter Note Additional capacity labels are provided with each unit If using a scale in the applicable lb oz mode or multi range kg mode install the correct label over the existing capacity markings...

Page 10: ...splays to indicates the scale is stable zero 1 5 3 Tare The tare function must be enabled in the configuration menu for the tare key to be functional The factory default setting is disabled 1 Place an...

Page 11: ...Place the scale on a sturdy level surface near a power outlet Ensure the scale or weight platter are not touching any objects 3 Level the scale by adjusting the leveling feet until the bubble level u...

Page 12: ...USB and RS 232 at the same time RS 232 USB Display Adapter Figure 2 1 BenchPro Connections 2 5 Primary Operator Display Mounting Options The primary operator display is included with each scale and c...

Page 13: ...AM ROM DIV A DIV O Diagnostics Done exit Note After selecting all parameter settings move to the parameter and press to confirm and save settings 3 2 Service Menu The service menu provides all configu...

Page 14: ...in non approved applications use this feature to return the scale to zero weight if in a high vibration environment Lo Med Hi Filter controls the weight display update rate used if the weight display...

Page 15: ...easure Applicable settings are dependant on the model of scale purchased see Section 1 4 on page 5 for available selections Most models have a minimum of two units of measure turned on To avoid incorr...

Page 16: ...tions may affect the accuracy of the BenchPro Series scale upon initial installation The scale includes a feature that allows for adjustment of the gravity setting to the location and reducing the nee...

Page 17: ...de and altitude Please note these website address are provided for reference only and may change National Geophysical Data Center www ngdc noaa gov Measurement Canada www ic gc ca Map Coordinates www...

Page 18: ...ce the weight platter back onto the scale is displayed 4 Press until is displayed 5 Press to accept or is displayed 6 Press to scroll to 7 Press to accept is displayed 8 Press is displayed 9 Use Table...

Page 19: ...instructed by Rice Lake Weighing Systems and an authorized scale technician The BenchPro Series includes an optional linear calibration feature This is an additional feature to perform after a span ca...

Page 20: ...ilize 22 Press to accept and perform Point2 calibration The calibration data is saved and the scale returns to the weigh mode The weight value displayed must match the value of the calibration weight...

Page 21: ...ice Lake Weighing Systems website 5 2 I O Specifications The BenchPro Series includes both a straight pass through RS 232 cable and USB Cable The functional pin out is as follows DE 9 Male Host Pin Na...

Page 22: ...gging into the USB port turn the scale on The following is displayed Table 5 3 USB Driver Install When the driver is installed using device manager the BenchPro Series will be identified as a HID comp...

Page 23: ...W l b sp W W o z CR LF H1 H2 CR ETX Request High Resolution weight 10x Command H CR 48h 0dh over capacity invalid data LF U U CR LF H1 H2 CR ETX under capacity LF U U CR LF H1 H2 CR ETX zero point er...

Page 24: ...e UNIT key lb kg LF U U CR LF H1 H2 CR ETX simulate UNIT key lb oz LF l b o z CR LF H1 H2 CR ETX Power off the scale Command X CR 58h 0dh simulate OFF key Unrecognized Command Command others xxh 0dh R...

Page 25: ...id data LF U U CR LF S H1 H2 H3 CR ETX under capacity 20d LF U U CR LF S H1 H2 H3 CR ETX zero point error Initial Zero LF U U CR LF S H1 H2 H3 CR ETX in lb oz kg g normal data LF p W W W W W U U CR LF...

Page 26: ...kg LF 2 CR ETX simulate TARE key oz LF 3 CR ETX simulate TARE key lb LF 4 CR ETX simulate TARE key lb oz LF 5 CR ETX Returns scale capabilities Command A CR 41h 0dh Response LF v w x y z CR ETX curren...

Page 27: ...b CR ETX capacity 6 kg LF 6 k g CR ETX capacity 15 kg LF 1 5 k g CR ETX capacity 35 kg LF 3 5 k g CR ETX capacity 50 kg LF 5 0 k g CR ETX capacity 75 kg LF 7 5 k g CR ETX capacity 150 kg LF 1 5 0 k g...

Page 28: ...ys 1 always 1 always 1 5 always 1 always 1 always 1 6 always 0 always1 always 0 7 parity parity parity 24 BenchPro Series Operation Manual 5 4 3 8213 Interface Protocol 8213 Protocol Request displayed...

Page 29: ...W W W W W U U CR in lb oz STX W l b W W W W W o z CR in lb oz STX W W l b W W W W o z CR in lb oz STX W W W l b W W W o z CR in lb oz STX sp W W W W l b W W o z CR Request scale to zero Command Z 5ah...

Page 30: ...Symbols Used STX start of test 02h CR carriage return 0Dh sp space 20h U U measure units lb oz kg g W W W W W weight data 5 6 Bytes Bit Definition Bit Status S 0 0 stable 1 no stable 1 0 not over cap...

Page 31: ...W W W U U CR in lb oz kg g STX W W W W W U U CR in lb oz kg g STX sp W W W W W U U CR in lb oz STX W l b W W W W o z CR in lb oz STX W W l b W W W o z CR in lb oz STX sp W W W l b W W o z CR Request c...

Page 32: ...eries Operation Manual 5 4 5 SMA Interface Protocol SMA Protocol Request displayed weight Command LF W CR 0Ah 57h 0dh in lb oz kg g normal data LF s r n m f W W W W W W W W W U U U CR in lb oz kg g LF...

Page 33: ...U U U CR in lb oz kg g LF s r n m f W W W W W W W W W U U U CR in lb oz kg g LF s r n m f W W W W W W W W W U U U CR in lb oz kg g LF s r n m f W W W W W W W W W W U U U CR in lb oz LF s r n m f W W W...

Page 34: ...W U U U CR Change units of measure Command LF U CR 0Ah 55h 0dh Response LF s r n m f W W W W W W W W W U U U CR Invoke scale diagnostics Command LF D CR 0Ah 44h 0dh Response LF r e c m CR About scale...

Page 35: ...y Command LF S CR 0Ah 53h 0dh Response LF s r n m f W W W W W W W W W U U U CR Symbols Used LF line feed 0Ah CR carriage return 0Dh sp space 20h s Z Center of Zero O Over Capacity U Under Capacity E Z...

Page 36: ...sp W W W W W U U CR H1 H2 ETX in lb oz LF p W l b sp W W W W o z CR H1 H2 ETX in lb oz LF p W W l b sp W W W o z CR H1 H2 ETX in lb oz LF p sp W W W l b sp W W o z CR H1 H2 ETX Initial Zero Error LF...

Page 37: ...fer compatibility with scale manufacturer type or protocol identified prior to installing a software upgrade Note UPS Worldship provides access only to COM ports 1 4 when using RS 232 to USB converter...

Page 38: ...yed is greater than the in Zero configuration Configuration error Invalid configuration settings Check configuration settings Overload error Too much weigh applied Perform calibration check LC mV Memo...

Page 39: ...461C 20 kg load cell Model BP 1214 15R only 179736 AL 2461C 10 kg load cell Model BP 1214 6R only Load cell torque 120 kgf cm 5 179188 Battery housing cover 6 179190 AA Battery holder 7 179191 Primary...

Page 40: ...n Condensing Communication RS 232 USB HID Other USB HID 1C19 0002 RS 232 Cable 10 DB 9 pin male to female straight pass through and null modem USB Cable 46 116 84 mm A B type USB cable Stainless Steel...

Page 41: ......

Page 42: ...I 54868 USA U S 800 472 6703 Canada Mexico 800 321 6703 International 715 234 9171 Europe 31 0 26 472 1319 Rice Lake Weighing Systems is an ISO 9001 registered company Rice Lake Weighing Systems Speci...

Reviews: