6.1.5 Weigh Mode Commands
The serial transmit weight data commands in
transmit data to the selected port on demand. The
SX
and
EX
commands are valid only in the weigh mode; all other commands are valid in either configuration or weigh modes.
Command
Description
Values
POWER
Determines if indicator automatically powers on when plugged in or if power key
must be pressed. Read only in weigh mode.
AUTO
MANUAL
BKLGHT
Controls the LCD backlight display.
Read only in weigh mode.
ON, OFF, AUTO
BKLGHT.AUTO
Controls the LCD backlight display auto off time.
Read only in weigh mode.
10SEC, 30SEC, 1MIN, 5MIN, 10MIN
BAT
Reads the battery level. Read only.
Current battery level in millivolts.
Table 6-9. MISC Commands
Command
Description
Response Format
UID
View and set unit ID when in configuration
In weigh mode, the value can be changed temporarily; it will reverts to
last saved value at next power up
nnnnnn
DATESET
View or set date
The response will be in the format, and using the separators, as
defined in configuration; to set, first query the date, then send
DATESET=
, in exactly the same format (use only two digits for
the year)
TIMESET
View or set time
The response will be in the format, and using the separators, as
defined in configuration; to set, first query the time, then send
TIMESET=
followed by the time in exactly the same format as
the query, including seconds, and AM or PM if in 12 hour format
SX
Start streaming on Port 2.
NOTE: The trigger mode of Port 2 must be set to one of the
five stream s for this command to function.
OK
or
??
EX
Stop streaming on Port 2
NOTE: The trigger mode of Port 2 must be set to one of the
five stream s for this command to function.
OK
or
??
RS
Soft reboot
See
XG
Transmit gross weight in displayed units
nnnnnn
UU
Where
nnnnnn
is the weight value,
UU
is the units
XG2
Transmit gross weight in non-displayed units
XE
Query system error conditions
nnnnn nnnnn
See
for detailed information about the
XE command response format
Table 6-10. Weigh Mode EDP Commands