![Rice Lake 482-AG Technical Manual Download Page 50](http://html1.mh-extra.com/html/rice-lake/482-ag/482-ag_technical-manual_1453829050.webp)
482-AG Livestock Digital Weight Indicator
46
Visit our website
7.0
Print Formatting
The 482-AG provides print format to determine the information to be printed on a ticket.
Each print format can be customized to include up to 300 characters of information, such as company name and address, on
printed tickets. The indicator front panel (
PFRMAT
menu) can be used to customize the print formats, see
The display will only show capital letters. Press the down arrow to view the ASCII character decimal value on the
to view the ASCII character charts.
7.1 Print Formatting Tokens
lists tokens that can be used to configure the print formats. Tokens included in the format strings must be enclosed
between < and > delimiters. Any characters outside of the delimiters are printed as text on the ticket. Text characters can
include any ASCII character that can be printed by the output device. The default 482-AG print formats are shown.
prints the gross weight in the units not currently displayed on the indicator.
The 300 character limit of each print format string includes the output field length of the print formatting tokens, not
the token length. For example, if the indicator is configured to show a decimal point, the <G> token generates an
output field of 13 characters: the 10 character weight value (including decimal point), one space, and a two-digit units
identifier.
Token
Description
<G>
Gross weight in displayed units
<G2>
Gross weight in non-displayed units ***
<UID>
Unit ID number
<CN>
Consecutive number
<NL
nn
>
New line (
nn
= number of termination (<CR/LF> or <CR>) characters)*
<SP
nn
>
Space (
nn
= number of spaces)*
<SU>
Toggle weight data format (formatted/unformatted) ** ***
<TI>
Time
<DA>
Date (prints 4 digit year)
<TD>
Time & Date
Gross weight is nine digits in length, including sign, 10 digits with decimal point, followed by a space and a two-
digit units identifier; The total field length with units identifier is 12 (or 13) characters
UID and consecutive number (CN) fields are six characters in length
* If
nn
is not specified, 1 is assumed; Value must be in the range 1–99
** After receiving an SU command, the indicator sends unformatted data until the next SU command is
received; Unformatted data omits decimal points, and leading and trailing characters
*** Not available if regulatory mode is set to OIML
Table 7-1. Print Format Tokens
Note
Note
Summary of Contents for 482-AG