![Rice Lake 420 Plus Installation Manual Download Page 30](http://html1.mh-extra.com/html/rice-lake/420-plus/420-plus_installation-manual_1453825030.webp)
26
420 Plus Installation Manual
Table 3-7. Setpoint Menu Parameters
SETPNT Menu
Parameter
Choices
Description
Level 2 submenus
SETPT1
SETPT2
ENABLE
KIND
VALUE
TRIP
BNDVAL
Specify settings for setpoint enable, kind, weight value, trip, and band value used by the
setpoint
Level 3 submenus
ENABLE
OFF
ON
Turn setpoint ON or OFF.
KIND
GROSS
NET
Specifies the setpoint kind and determines whether function is based on GROSS or NET
weight.
GROSS or NET setpoint kinds can be used.
VALUE
number
Display and edit the setpoint value
TRIP
HIGHER
LOWER
INBAND
OUTBND
Trips the setpoint when the weight is higher or lower than the setpoint value, or is within or
outside of the band value. LOWER means the output is active until you reach weight. If trip is
HIGHER, the output is active when the setpoint is met or exceeded. INBAND means the
output is active if the weight is within the band value. If trip is OUTBND, the output is active
when the weight is outside of the band value.
BNDVAL
number
The band value for either INBAND or OUTBND trip setpoints. BNDVAL is ignored unless trip is
set to INBAND or OUTBND.
HYSTER
number
Specifies a band around the setpoint value that must be exceeded before the setpoint, once
off, can trip on.
ACCESS
OFF
ON
Front panel access to setpoints. Specify OFF if setpoints will not be used. ON enables
operator to turn setpoints on/off, change value, or change BANDVAL via front panel entry
during weigh mode.