background image

EN -

 Original instructions

 

I. Parts List 
II. Characteristics 

III. Safety instructions 
IV. Getting Started 

V. Operation 
VI. Maintenance and Storage 

 

I. PARTS LIST 

See Fig. 1

 

 

II. CHARACTERISTICS 

See Table 1

 

 

III. SAFETY INSTRUCTIONS 

 
Before using this product, read and understand all safety instructions. 
Always follow the safety instructions to minimize risk of damage to property, and to minimize 
any risk of damages and injuries to persons and animals. 
Keep manual for future reference. 

 

Symbols

 (

Explanation of symbols appearing on the tool, if applicable). 

 

Caution! Risk of injury and/or damage and/or deterioration of product in case of 
non-compliance to safety requirements 

 

Read the instructions manual.  
 

 

Keep persons (esp. children) and animals away from product and working area 

 

Disconnect product from its power source before maintenance, cleaning or any 
intervention on product; or when you do not use product. 
Disconnect product from its main power source, if product, power cable, or extension 
cord is damaged or cut during operation. 
Unplug product by pulling the plug. Do not pull the cable. 

 

Do not dispose of this product with household rubbish. 
Dispose of this product in the nearest recycle centre. 
Please contact your local authority or local recycle centre for further information for 
its safe disposal. 

 

3.1- READ ALL THE INFORMATION BEFORE OPERATING THE PRODUCT. 

1. Keep work area clean

 

Cluttered areas and benches invite accidents and injuries.

 

2. Consider work area environment

 

Keep work area well lit (natural light or sufficient artificial lighting). 
Keep work area well ventilated. 
Do not use product where there is risk to cause fire or explosion (in the presence of flammable liquids, 
solids or gas).

 

3. Guard against electric shock

 

Avoid body contact with earthed or grounded surfaces (e.g. pipes, radiators, ranges, refrigerators).

 

4. Keep children away

 

Do not let bystanders touch the product or its power cable or extension cord.  
All bystanders (esp. children) should be kept away from product and work area. 
Keep the product away from children or from their environment. Never allow children to operate the 
appliance. Children should be supervised to ensure that they do not play with the appliance. 
5. Store idle products 
When not in use, product should be stored in a dry, high or locked up place, out of reach of children. 
6. Do not force the product 
It will do the job better and safer at the rate speed for which it is intended. 
Do not use the product for purposes other than those for which it is intended. The product will do a 
better and safer job if it is used only for the purposes it was designed for. 

Summary of Contents for RIBILAND PRPVC401SP

Page 1: ...MERSIBLE PUMP User and maintenance manual IT POMPA SOMMERSA Manuale di istruzioni e di manutenzione R f Art Nr PRPVC401SP 511366 Imp par by Ribimex S A 56 Route de Paris FR 77340 Pontault Combault Imp...

Page 2: ...ury and or damages Please keep this manual for future reference AVVERTENZA Leggere attentamente questo manuale di istruzioni prima di utilizzare l attrezzo Il funzionamento non corretto pu causare les...

Page 3: ...centre de recyclage le plus proche Demander conseil aux autorit s locales ou votre d chetterie locale 3 1 LIRE TOUTES LES INSTRUCTIONS AVANT D UTILISER CE PRODUIT 1 Garder l aire de travail propre De...

Page 4: ...s re performance 13 D connecter le produit Quand il n est pas utilis avant un entretien et pour changer les accessoires 14 Eviter les d marrages intempestifs S assurer que l interrupteur est en posit...

Page 5: ...iques 3 3 Recommandations et instructions de s curit 1 La tension d alimentation doit correspondre celle indiqu e sur l tiquette des caract ristiques 230V 50Hz N utiliser aucun autre type d alimentati...

Page 6: ...veau d eau doit tre 5mm Pour mettre en route la pompe brancher la prise Pour arr te la pompe d brancher la prise 3 positions auto mise en route automatique de la pompe selon le niveau d eau et le r gl...

Page 7: ...eur en position haute voir Fig 4 Pour d marrer et teindre la pompe brancher et d brancher la prise de l alimentation Note dans ce cas la hauteur d eau minimum aspirable peut tre r duite 5mm 5 2 3 Atte...

Page 8: ...oulement trop haute 2 Orifice d aspiration bloqu e 3 Usure de la turbine 4 Immersion trop faible et aspiration d air 5 Tuyau de refoulement mal connect fuit ou est us 1 Ajuster la hauteur recommand e...

Page 9: ...contact your local authority or local recycle centre for further information for its safe disposal 3 1 READ ALL THE INFORMATION BEFORE OPERATING THE PRODUCT 1 Keep work area clean Cluttered areas and...

Page 10: ...rds intended for outdoor use 16 Stay alert Watch what you are doing Use common sense Do not operate product when you are tired under the influence of alcohol prescription medicines or drugs 17 Check d...

Page 11: ...The pump should be supplied by a circuit containing a residual current circuit breaker RCCD with a sensitivity not exceeding 30 mA Consult a qualified electrician 3 The supply cable should be checked...

Page 12: ...necting the plug to the mains In this position the water level must be greater than 5mm The pump will suck water up to 1mm To stop the pump pull out the sensor switch or pull the power plug 3 position...

Page 13: ...h to upper position see Fig 4 To operate the pump connect and disconnect plug to mains socket Note in this case the minimum pumping water height is reduced to 5mm 5 2 3 Warning The pump is not designe...

Page 14: ...hole clogged 3 Impeller worn badly 4 Submersion too shallow and air sucked in 5 Discharge hose disconnected leaking or worn out 1 Use within the rated head range 2 Remove water weed or foreign matter...

Page 15: ...bolo devono essere adeguatamente smaltiti in modo da assicurarne il riciclaggio Contattare l ente locale preposto o l azienda incaricata per ulteriori informazioni sul metodo sicuro di smaltimento 3 1...

Page 16: ...vio accidentale del dispositivo Accertarsi che l interruttore sia spento quando il dispositivo collegato alla rete principale 15 Uso delle prolunghe Quando l attrezzo utilizzato con una prolunga utili...

Page 17: ...ata stilla targhetia delle carattcrisliche 230V 50Hz Non usate nessun altro tipo di alimentazione 2 La pompa deve essere alimentata da un circuito dotato di un dispositivo di corrente differenziale DC...

Page 18: ...er arrestare la pompa scollegare la spina dalla presa 3 posizioni auto che consente la messa in funzione automatica della pompa secondo la posizione selezionata e l orientamento del sensore In posizio...

Page 19: ...mpa collegare e scollegare la spina della presa di rete Nota in questo caso l altezza minima di aspirazione pu essere ridotto a 5mm 5 2 3 Attenzione La pompa non prevista per un utilizzo in continuo 5...

Page 20: ...uito di aspirazione bloccato 3 Usura della turbina 4 Immersione troppo basso e aspirazione dell aria 5 Tubo di scarico male scollegato perdite o usurati 1 Regolare l altezza consigliata 2 Liberare o p...

Page 21: ...imentation Power cable Cavo elettrico 4 Raccord universel Universal Fitting Raccordo universale 5 Trou d vent Vent valve Dispositivo d evacuazione 6 Trou d aspiration Suction base Fori di aspirazione...

Page 22: ...y height Altezza max di scarico 7m Profondeur d immersion maxi Max submersion depth Profondita di immersione max 7m Hauteur mini de liquide pour l aspiration Min water level for operation Altezza mini...

Reviews: