I. PARTS LIST
See Fig.1
II. CHARACTERISTICS
Reference
PRSSME / 511356
Model / Type
HYWK-0402
Voltage & frequency
250V ~ 50Hz
Current max
8(6)A
Min pressure for operation
0.6 bar (0.06MPa)
Max. pressure
6 bars (0.6MPa)
IP protection class
IP44
Inlet/outlet diameter
1" (26x34)
Electric cable
H07RN-F 3G1.0mm
2
x 1,20m
Max fluid temperature
40
C
Weight (approx.)
0,6kg
III. SAFETY INSTRUCTIONS
Before using this product, read and understand all safety instructions.
Always follow the safety instructions to minimize risk of damage to property, and to minimize any
risk of damages and injuries to persons and animals.
3.1- Symbols
Caution! Risk of injury and/or damage and/or deterioration of product in case of non
compliance to safety requirements
Read the instructions manual.
Keep persons (esp. children) and animals away from product and working area
Disconnect product from its power source before maintenance, cleaning or any
intervention on product; or when you do not use product.
Disconnect product from its main power source, if product, power cable, or extension
cord is damaged or cut during operation.
Unplug product by pulling the plug. Do not pull the cable.
Do not dispose of this product with household rubbish.
Dispose of this product in the nearest recycle centre.
Please contact your local authority or local recycle centre for further information for its
safe disposal.