PROBLEM
CHECK
All of the LEDs on the MASTER Wi-Fi are off
Ensure that 12 or 24 V ac/dc power is present to the power feed terminals of the
MASTER Wi-Fi
During memorization of the safety devices the buzzer sounds for 3/5 second
It has been tried to memorize a safety device with wrong microswitch.
Verify that the dual-color led that flashes on MASTER Wi-Fi corresponds at the safety
device microswitch to memorize.
During memorization of the safety devices the buzzer sounds 2 twice
A safety device is already in the memory
When giving a command the buzzer sounds 3 times
- No safety device has been memorized, memorize at least one, OR
-
The DIP corresponding to the safety devices memorized on the MASTER Wi-Fi card
are OFF. Turn them to ON
When giving a command the buzzer sounds 4 times
Possible cable missing between the MASTER Wi-Fi and the door control card:
- Blinker to card connection wires detached, OR
- Strip to card connection wires detached, OR
- Photocell to card connection wires detached, OR
- Radio control for pedestrian gate opening not completely closed
The buzzer sounds 5 times when the strip connected to the photocell receiver is
pressed
Contact configuration error with the strip connected to the photocell receiver
When giving a command the buzzer sounds 5 times
-
Resistance not connected in series with the N.C. contact of the strip connected to
the photocell receiver, OR
- Wires detached on the strip with N.O. contact, OR
- Resistance not connected in series with the N.C. contact of the strip, OR
- Wires detached on the strip with N.O. contact connected to the photocell receiver
The buzzer emits a sound every 3 seconds and the blinker during the gate operation
flashes 2 times in succession followed by a pause of 3 seconds for 1 minute and one
of the dual-color leds is ignited red fixed
Replace the batteries of the photocell(s) or the strip(s) as they are low
The gate doesn’t move, the buzzer emits an alternating sound and the blinker
flashes 2 times in succession followed by a pause of 3 seconds for 1 minute and one
of the dual-color leds is ignited green-red alternated
Replace the batteries of the photocell(s) or the strip(s) as they are exhausted
LED DL2 is off and one of the dual-color LED EDGE emits a constant green light
- Wires detached on the strip with N.C. contact, OR
-
Ensure that there is resistance of 8,2kΩ in series with the N.O. contact of the strip
connected to the photocell receiver
The buzzer does not sound when the batteries are removed from the strip
Ensure that the micro-switch on the MASTER Wi-Fi corresponding to the strip is in
the ON position
The door does not open or close and one of the dual-color LEDs emits a constant
green light
-
Photocell is not aligned or it is engaged. The batteries in the photocell transmitter
are exhausted, OR
-
Resistance of 8,2 kΩ is not connected in series with the N.C. contact or in parallel
with the N.O. contact of the strip connected to the photocell transmitter, OR
-
Resistance of 8,2 kΩ is not connected in parallel with the N.O. contact of the strip
connected to the photocell transmitter
The door does not open or close, the buzzer emits an alternating sound and the
blinker flashes 2 times in succession followed by a pause of 3 seconds for 1 minute
and one of the dual-color LEDs alternates red and green
Photocell or strip receiver batteries are exhausted
The strip connected to the photocell transmitter or receiver does not work as a safety
device
Check the correct setting of the jumper of the photocell transmitter/receiver. If the
jumpers are correctly setting, remove and put again the batteries.
T
ECHNICAL SPECIFICATIONS
- POWER
12/24 Vac/dc
- APPLICABLE TENSION ON CONTACT J4 120/220/230V 50/60Hz
- APPLICABLE TENSION ON CONTACT J2 12/24V ac/dc
- ABSORPTION AT REST
40 mA
- MAXIMUM ABSORPTION
100 mA
- WORKING TEMPERATURE
-20°C ÷ +60°C
- SIZE
96x43x20 mm
(code ACG6094)
- WEIGHT
0,042 kg
(code ACG6094)
- SIZE
125x55x28 mm
(code ACG6099)
- WEIGHT
0,090 kg
(code ACG6099)
SAFETY DEVICES AND SIGNALING RADIO FREQUENCY SIGNAL
TECHNICAL INFORMATION
- FREQUENCY
868,3 MHz
- SENSITIVITY
-108 dBm
- EMITTING POWER
<25 mW
- MODULATION TYPE
FSK
- RANGE
20 m in open spaces
COMMAND ACTIVATION RADIO FREQUENCY SIGNAL TECHNICAL
INFORMATION
- FREQUENCY
433,92 MHz
- SENSITIVITY
-107 dBm
- MODULATION TYPE
OOK
- RANGE
100 m in open spaces with antenna