![RIB KS2 12-24V Assembly Instructions Manual Download Page 16](http://html.mh-extra.com/html/rib/ks2-12-24v/ks2-12-24v_assembly-instructions-manual_1453088016.webp)
E
N
G
L
I
S
H
Pag. 16 di 32
ELECTRIC CONNECTIONS
WARNING!
The length of connection cables from the motors to the control panel unit must not exceed 15 m.
The wire section of the motor power supply must be 1.5 mm
2
, whilst that of the accessories must be 0,75 mm
2
.
As for the encorder it is very important to use a shielded wire with a section of 0,75 mm
2
type ÖLFLEX-110 CH.
It is compulsory to use shielded cable for the encoder in order to guarantee the correct operation of the control board.
The screen of the ENCODER cable must be earth grounded at one end (not to the card GND), and at the opposite end the screen must be
free (conductor not connected).
To ensure the correct functioning of the installation it is advisable to wire encoder and motor with separate cables.
ENCODER
1 -> S
2 -> +
3 -> GND
1-2 => M
KING
PRINCE
Where:
=>
WHITE-RED-BLU
E are the plugs of the connector
where you have to insert the 3 WIRES (NOT THE
SHIELD !)
=>
S, +, GND
are the plugs of the control board where
you have to insert the 3 WIRES. The SHIELD must be
inserted togheter with the 3rd wire in the GND plug into
the control board.