32
B - SETTINGS
DIP 1 (ON) - MOTOR ROTATION DIRECTION CONTROL (POINT C)
DIP 2 (ON) - TIMER (POINT D)
DIP 3
(ON) - ACTIVATES DOOR RELEASE DURING PHASES OF SLOWDOWN AND
TOTAL OPENING AND CLOSING (AS PER THE IMPACT TESTS OF EN12453)
DIP 1-2
MEMORIZATION/CANCELLATION OF RADIO CONTROL CODES FOR TOTAL
OPENING (ONLY MODEL CRX) (POINT E)
DIP 1-3
MEMORIZATION/CANCELLATION OF RADIO CONTROL CODES FOR PEDESTRIAN
OPENING (ONLY MODEL CRX) (POINT F)
DIP 2-1
MICRO-SWITCH CONTROLLER FOR PEDESTRIAN OPENING TIMER
DIP 4
Photocells always active (OFF) - Photocells active only during closing (ON)
DIP 5
Pre-blinking (ON) - Normal blinking (OFF)
DIP 6
Single pulse command (K BUTT) and step-by-step radio receiver (OFF) - automatic
(ON)
DIP 7
Power sensor operation (ON-activated) time operation (OFF-activated).
DIP 8
Electric lock activation (ON-activated)
DIP 9
Electric lock pulse release (ON-activated)
DIP 10
Electric lock pulse engagement (ON-activated)
DIP 11
Easy release activation (ON-activated)
DIP 12
Sensor TEST activation (ON-activated).
DIP 13
Selection of 1 or 2 motor operation (default OFF 2 motors)
DIP 14 OFF
DIP 15 OFF
DIP 16
IMMEDIATE CLOSING AFTER PASSING IN FRONT OF PHOTOCELLS
ON ACTIVATED
OFF DEACTIVATED
JP1 =>
Check that the jumper is inserted!
JP2 =>
Check that the jumper is inserted!
JP3 =>
Check that the jumper is inserted!
PROG =>
S3 Programming button
ADJUSTMENTS
ATTENTION: PUT DIP 3 IN THE ON MODE ONLY AFTER HAVING CARRIED OUT ALL THE
PROGRAMMING PROCEDURES.
NOTE: WITH DIP 3 (ON) BRIEF GATE REVERSAL AFTER IMPACT IS ACTIVATED.
THIS BRIEF GATE REVERSAL PERMITS STATIC FORCE TO BE REDUCED TO ZERO WITHIN
5 SECONDS AS PER STANDARD EN12453 POINT A.2.2 (ACCEPTABLE STATIC FORCE),
THEREBY COMPLYING WITH THE IMPACT TESTS ALSO OUTLINED BY EN12453).
IF COMPLIANCE WITH THE AFOREMENTIONED STANDARD IS UNNECESSARY, SIMPLY
POSITION DIP 3 TO OFF. IN THIS CASE THE GATES STOP WITHOUT REVERSING.
RUN TRIMMER (TR1) high-speed electronic regulator
This trimmer permits motor speed adjustment (the default setting is maximum speed).
Adjustment of the automation is useful for compliance with European impact standards.
LOW-SPEED TRIMMER (TR2) Electronic slow speed approach control
The slow speed control is performed by adjusting the LOW- SPEED TRIMMER which changes
the voltage output across the motor(s) (turning it clockwise increases the speed). Adjustment
is performed to determine the correct speed at the end of opening and closing according to
the gate or when there is friction that might cause the system to function poorly.
AUTOMATIC CLOSING TRIMMER - TCA (TR3) TOTAL OR PEDESTRIAN default NOT
ACTIVATED and LED DL6 OFF (TRIMMER FULLY ROTATED COUNTERCLOCKWISE)
This trimmer makes it possible to adjust the time for total or pedestrian automatic closing.
G
B
J1
N F
Power supply 230 Vac 50/60 Hz - external to the
control panel - (120V/60Hz upon request)
J2
COM.
Common contact
CLOSE
Closing impulse contact (NA)
OPEN
Opening impulse contact (NA)
STOP
STOP impulse contact (NC)
AERIAL
Radio Antenna
SIGNAL
Gate open state and battery state output indicator
(24Vdc 3W max)
J3
A+TEST
+ 24Vdc safety strip self-test power supply
EDGE N.C.
Safety strip contact (NC)
COM.
Common contact
PHOTO N.C.
Photocells contact (NC)
K BUTT.
Single pulse contact (NO)
PED. BUTT.
Pedestrian opening contact (NA)
A+
+ 24Vdc accessories power supply
A -
- 24Vdc accessories power supply
LOCK
Electric lock connection (MAX 15W 12V)
- 24Vdc blinker (code ACG7061) power supply. Pay
attention to the polarity.
J4
SECONDARY
TRANSFORMER
Connection to secondary coil of transformer 18 Vac
J5
MOTOR 1
MOTOR 1 CONNECTION (without polarity)
J6
MOTOR 2
MOTOR 2 CONNECTION (without polarity)
J7
SW T2 24V
Connector dedicated to the factory programming.
DO NOT REMOVE ANY JUMPER! OTHERWISE THE
OPERATOR WILL NOT WORK!
J8
SW RADIO
Connector dedicated to the factory programming (only
CRX control board) DO NOT REMOVE ANY JUMPER!
OTHERWISE THE OPERATOR WILL NOT WORK!
J9
RADIO
Built-in radio module (model CRX), or connector for
radio receiver RIB, 24 Vdc supply
J10
BATTERY CHARGER
Connector for charge card of 24Vdc battery (code
ACG4648)
TR1
TRIMMER RUN
Trimmer for high speed adjustment operations
TR2
TRIMMER LOW SPEED Trimmer for low speed adjustment operations
TR3
TRIMMER TCA
Trimmer for automatic closing time adjustment
(DISABLED DEFAULT AND DL6 LED OFF)
S3
PROG
Programming button
FUSE 1
T 8 A
Motor protection fuse
F1
T 2 A
Transformer protection fuse
A - CONTROL PANEL FEATURES
J3
TR2
TR1
J2
J4
F1
FUSE 1
J5
J6
TR3
J10
J8
J9
J1
J7
S3
TRANSFORMER