Operative Instructions
33
ID
Parameter Name
Min
Max
Description
Factory
Default
Only with
techni-
cian*
5
Water filling timeout*
3
10
Maximum time for fill the
tank
5 min
YES
6
Detergent time L1*
0.4
1
18
45
Dosing with tank at minimum
level
7.2 sec
18.0 ml
YES
7
Detergent time L2*
0.4
1
18
45
Dosing with tank at maximum
level.
14.4 sec
36 ml
YES
8
Language
1
8
Selects the desired language
for the display.
1
NO
9
Buzzer
OFF
ON
Enables or disables the
acoustic signal.
ON
NO
10 Open temperature
25
100
This set the temperature value
at which the door can be
opened.
88°C
YES
11 Ev. steam temperature
0
100
This set the temperature value
at which the “Steam Solenoid
Valve” output trips.
75°C
YES
12 Minimum hysteresis
1
5
Minimum temperature value
that must be maintained
during disinfection.
2°C
YES
13 Maximum hysteresis
2
6
Maximum temperature value
that must not be exceeded
during disinfection.
3°C
YES
14 Time solvent
0.1
0.5
20.0
100.0
This set the time/dosing that
the solvent pump operates.
5.0 sec
25.0 ml
YES
15 Action solvent
0
200
This set the time the solvent is
left to work.
30 sec
YES
16 Solvent repetition
1
9
This indicate the number of
repetitions of the solvent
cycle.
1
YES
17 Time open door
0
25.0
This set the time the door
takes to open up at the end of
the cycle.
2.0 sec
YES
18 Time A_system
0
12000
Time value for which the
ventilation system works.
60 sec
YES
19 A_system delay
0
65000
Time delay for A_System.
0 sec
YES
20 Autodisinfection
0
7
Choose which program starts
automatically every 24 hours
for disinfection.
3
NO
Summary of Contents for DVS
Page 40: ...Operative Instructions 40 Notes ...
Page 41: ...Operative Instructions 41 Notes ...