3. BEFORE INSTALLATION
Receiving Equipment
The manufacturer recommends that this manual be
reviewed thoroughly before installing your pool/spa
heater. If there are any questions that this manual does
not answer, please contact the factory or your local
representative.
On receipt of your equipment it is suggested that you
visually check for external damage to the carton. If the
carton is damaged, a note should be made on the Bill
of Lading when signing for the equipment. Remove the
heater from the carton. If it is damaged, report the damage
to the carrier immediately. Save the carton.
These items are shipped inside a box in the carton with
the heater:
STANDARD UNIT
1. Bypass assembly P/N 015459F
2.
Bonding lug with mounting screw
3. 4" Intake air adapter P/N 015527F (not shown)
4.
PVC/Polypropylene/Stainless Steel vent adapter
P/N 015508F
5. (2) 2" CPVC Plugs (not shown)
6. (4) Mounting screws and (4) washers
7. (2) Bird screens (not shown)
8.
4" Sch 40 PVC Tee and
5" (127 mm) L x 4” diameter Sch 40
PVC vent pipe P/N 015451
9. (2) 2" CPVC Swivel Unions P/N 015464F
Be sure that you receive the number of packages indicated
on the Bill of Lading.
When ordering parts, you must specify the model and
serial numbers of the heater. See
Figure 2
for location of
serial number. When ordering under warranty conditions,
you must also specify date of installation.
2" NPT ADAPTER
O-RING
2" SLIP TAILPIECE
UNION LOCKRING
BONDING LUG
W/ MTG SCREW
UNION P/N 015464F
BYPASS ASSEMBLY
P/N 015459F
VENT ASSEMBLY
P/N 015451
F10317
FLUE ADAPTER
P/N 015508F
WASHER
MOUNTING
SCREW
F10318
Figure 1. Standard Unit
MODEL & SERIAL
NO. LOCATED ON
RATING PLATE
MODEL & SERIAL NO.
CAN ALSO BE FOUND
INSIDE THE UNIT ON THE
LEFT FRONT SUPPORT
SERIAL
NUMBER
F10319
Figure 2. Serial No. Location
Ratings and Certifications
These heaters are design-certified and tested under the
latest requirements of the ANSI Z21.56 / CSA 4.7 Standard
for Gas-Fired Pool Heaters. All heaters can be used either
indoor or outdoors. The heat exchanger bears the ASME
H-stamp and is National Board registered.
Ambient Temperature Rating
•
Electronics and controls -32°F to +175°F (-35.5°C to
+79.5°C)
•
Condensate drains and trap* +32ºF to 175ºF (0°C to
79°C)
*The heater must be in a non-freezing environment
to operate properly. Frozen condensate may damage
components. Winterize the heater prior to prolonged
exposure to freezing temperatures.
Elevation
Rated inputs are suitable for up to 4,500’ (1,371 m)
elevation. At elevations above 4500 feet (1,371 m) the
input will be reduced by approximately 2.5% for each
1,000’ (304.8 m) above sea level as high elevation reduces
APPROVED
UNCONTROLLED DOCUMENT IF PRINTED
Summary of Contents for Raypak X94 SR-410
Page 26: ...26 5 WIRING DIAGRAM APPROVED UNCONTROLLED DOCUMENT IF PRINTED...
Page 42: ...42 Control Logic Flow Chart Pool Spa Modes APPROVED UNCONTROLLED DOCUMENT IF PRINTED...
Page 43: ...43 10 ILLUSTRATED PARTS LIST APPROVED UNCONTROLLED DOCUMENT IF PRINTED...
Page 51: ...51 NOTES APPROVED UNCONTROLLED DOCUMENT IF PRINTED...