background image

5

2.  IMPORTANT SAFETY 

INSTRUCTIONS

Entrapment Prevention

A

A

DANGER: 

DO NOT BLOCK SUCTION.

A

A

DANGER: 

Hazardous  suction  can 

trap hair or body parts, causing severe 

injury or death. Do not block suction.

SUCTION HAZARD

. Can cause serious injury or death. 

Do  not  use  this  pump  for  wading  pools,  shallow  pools, 

or  spas  containing  bottom  drains,  unless  the  pump  is 

connected to at least two functioning suction outlets.

A

A

WARNING:

  Pump  suction  is  hazardous  and  can 

trap and drown or disembowel bathers. Do not use or 

operate swimming pools, spas, or hot tubs if a suction 

outlet cover is missing, broken, or loose.

The  following  guidelines  provide  information  for  pump 

installation  to  minimize  risk  of  injury  to  users  of  pools, 

spas, and hot tubs.

Entrapment Protection

The pump suction system must provide protection against 

the hazards of suction entrapment.

Suction Outlet Covers

All  suction  outlets  must  have  screw-fastened  covers 

installed.  All  suction  outlet  (drain)  covers  must  be 

maintained.  Drain  covers  must  be  listed/certified  to  the 

latest published edition of ANSI/ASME A112.19.8 (ANSI/

APSP-16,  2011).  They  must  be  replaced  if  cracked, 

broken, or missing.

Number of Suction Outlets Per Pump

Provide  at  least  two  hydraulically-balanced  main  drains, 

with covers, as suction, for each circulating pump suction 

line. The centers of the main drains (suction outlets) on 

any  one  suction  line  must  be  at  least  3  ft  (.9  m)  apart, 

center to center.
The system must be built to include at least two suction 

outlets (drains) connected to the pump whenever the pump 

is running. However, if the two main drains run into a single 

suction line, the single suction line may be equipped with a 

valve that will shut off both main drains from the pump. The 

system shall be constructed so that it shall not allow for 

separate or independent shutoff or isolation of each drain.

More than one pump can be connected to a single suction 

line as long as the requirements above are met.

Water Velocity

The  water  velocity  through  the  suction  fitting  or  cover 

for any suction outlet must be 1.5 ft (.5 m) per second or 

less, unless the outlet complies with the latest published 

edition of ANSI/ASME A112.19.8 (ANSI/APSP-16, 2011), 

the standard for Suction Fittings For Use in Swimming and 

Wading  Pools,  Spas,  Hot  Tubs,  and  Whirlpool  Bathtub 

Applications.  In  any  case,  do  not  exceed  the  suction 

fitting's maximum designed flow rate.
If  100%  of  the  pump’s  flow  comes  from  the  main  drain 

system, the water velocity in the pump suction hydraulic 

system must be 6 ft (1.8 m) per second or less, even if one 

main drain (suction outlet) is completely blocked. The flow 

through the remaining main drain(s) must comply with the 

latest published edition of ANSI/ASME A112.19.8 (ANSI/

APSP-16, 2011), the standard for Suction Fittings For Use 

in  Swimming  and  Wading  Pools,  Spas,  Hot  Tubs,  and 

Whirlpool Bathtub Applications.

Testing and Certification

Suction outlet covers must have been tested by a nationally- 

recognized testing laboratory and found to comply with the 

latest published edition of ANSI/ASME A112.19.8 (ANSI/

APSP-16, 2011), the standard for Suction Fittings For Use 

in  Swimming  and  Wading  Pools,  Spas,  Hot  Tubs,  and 

Whirlpool Bathtub Applications.

Fittings

Fittings  restrict  flow;  for  high  efficiency  use  the  fewest 

possible fittings (but at least two suction outlets).
Avoid fittings that could cause an air trap.
Pool  cleaner  suction  fittings  must  conform  to  applicable 

International  Association  of  Plumbing  and  Mechanical 

Officials (IAPMO) standards.

CONTROLLED COPY approved for factory use on 4/16/2020.  RAYPAK PROPRIETARY AND CONFIDENTIAL INFORMATION .  Approval signatures on file in Engineering.

Summary of Contents for Raypak RPAGP100

Page 1: ...d experienced in the installation and maintenance of this type of equipment and related system components Installation and service personnel are required by some states to be licensed Persons not qual...

Page 2: ...ion to these Terms 3 2 IMPORTANT SAFETY INSTRUCTIONS 5 Entrapment Prevention 5 3 OVERVIEW 6 Constant Speed Pump Models 6 Dual Speed Pump Models 6 4 INSTALLATION 6 Pump 6 5 START UP 8 6 GENERAL MAINTEN...

Page 3: ...well as disinfectant feed ratios A AWARNING DO NOT increase pump size this will increase the flow rate through the system and exceed the maximum flow rate stated on the drain cover A AWARNING Before i...

Page 4: ...interrupter GFCI should always be installed at the power supply source of this unit Article 681 31 of the NEC requires that a GFCI be used if this pump is used with a storage pool Be sure to ground t...

Page 5: ...drains from the pump The system shall be constructed so that it shall not allow for separate or independent shutoff or isolation of each drain More than one pump can be connected to a single suction...

Page 6: ...pump is used with a storage pool Be sure to ground the motor before connecting it to an electrical AC power source Failure to ground the motor can cause serious or fatal electrical shock hazard DO NO...

Page 7: ...RPAGP100 0 75kW 1 0 Single RPAGP102 0 75kW Max 1 0 Dual RPAGP150 1 1kW 1 5 Single RPAGP152 1 1kW Max 1 5 Dual DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this...

Page 8: ...pressure from the system before proceeding 2 Unscrew the trap lid pre filter lid by turning counterclockwise 3 Remove the strainer basket and clean it Be sure all holes in the basket are unclogged th...

Page 9: ...tion or discharge line is partly closed Open or replace the valve Suction or discharge line is partly plugged Clear the obstruction Suction or discharge line is too small Re plumb use a larger pipe di...

Page 10: ...50F Kit Pump Impeller RPAGP150 152 018251F 6 7 018225F 018227F 5 Kit Transparent Cover AGP Kit Mechanical Seal 1 2 with O Ring Table C Replacement Parts 1 2 3 4 6 7 5 Figure 3 Pump with Motor Exploded...

Page 11: ...ak com warranty then the Applicable Warranty Period is one 1 year from the Effective Date for the PUMP and component parts LABOR AND SHIPPING COSTS This Limited Warranty does NOT cover any travel time...

Page 12: ...ES ON RAYPAK S BEHALF ANY IMPLIED WARRANTIES INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL NOT EXTEND BEYOND THE APPLICABLE WARRANTY PERIOD SPECIFIED IN THIS LIMITED WARRANTY RAY...