1.  WARNINGS 

Pay Attention to these Terms

A

A

DANGER

Indicates the presence of immediate hazards which will cause severe personal injury, death or substantial 

property damage if ignored.

A

A

WARNING 

I

ndicates the presence of hazards or unsafe practices which could cause severe personal injury, death or 

substantial property damage if ignored.

A

A

CAUTION

Indicates the presence of hazards or unsafe practices which could cause minor personal injury or product 

or property damage if ignored.

CAUTION

CAUTION used without the warning alert symbol indicates a potentially hazardous condition which could 

cause minor personal injury or product or property damage if ignored.

NOTE

Indicates special instructions on installation, operation, or maintenance which are important but not related 

to personal injury hazards.

A

A

DANGER: 

Serious bodily harm or death can result if 

this pump and motor is not installed and used correctly.

A

A

WARNING:

 Risk of electrical shock. More than one 

disconnect  switch  may  be  required  to  de-energize  the 

equipment before servicing.

A

A

WARNING:

 This pump and motor is intended for use 

in swimming pool applications.

A

A

WARNING:

 Most states and local codes regulate the 

construction, installation, and operation of public pools 

and spas, and the construction of residential pools and 

spas. It is important to comply with these codes, many 

of which directly regulate the installation and use of this 

product. Consult your local building and health codes 

for more information.

A

A

WARNING:

 Do not permit children to use or operate 

this pump and motor.

A

A

WARNING:

  When  setting  up  pool  water  turnovers 

or  flow  rates  the  operator  must  consider  local  codes 

governing turnover as well as disinfectant feed ratios.

A

A

WARNING:

  DO  NOT  increase  pump  size,  this  will 

increase the flow rate through the system and exceed 

the maximum flow rate stated on the drain cover.

A

A

WARNING:

  Before  installing  this  product,  read 

and follow all warnings notices and instructions in this 

manual. Failure to follow warnings and instructions can 

result in severe injury, death, or property damage. Please  

call 1-877-213-3726 or refer to www.raypak.com for more 

information related to this product.

A

A

WARNING:

  Improper  installation,  adjustment, 

alteration, service, or maintenance can cause property 

damage, personal injury or loss of life. 

A

A

WARNING:

 A  pool  or  spa  pump  must  be  installed 

by  a  qualified  pool  and  spa  service  professional  in 

accordance  with  the  National  Electrical  Code  and 

all  applicable  local  codes  and  ordinances.  Improper 

installation may cause and electrical hazard which could 

result in death or serious injury to pool users, installers, 

or  others  due  to  electrical  shock,  and  also  cause 

property damage.

A

A

WARNING:

 Pumps are not a substitute for properly 

installed and secured pool drain covers. An ANSI/ASME 

A112.19.8  approved  anti-entrapment  drain  cover  must 

be used for each drain. Pools and spas should utilize a 

minimum of 2 drains per pump. If a drain cover becomes 

loose,  broken,  or  is  missing,  close  the  pool  or  spa 

immediately  and  shut  off  the  pump  until  an  approved 

anti-entrapment  drain  cover  is  properly  installed  with 

the manufacturer's supplied screws.

A

A

WARNING:

  Pump  suction  is  hazardous  and  can 

trap and drown or disembowel bathers. Do not use or 

operate swimming pools, spas, or hot tubs if a suction 

outlet cover is missing, broken, or loose.

A

A

DANGER: 

Hazardous  suction  can 

trap hair or body parts, causing severe 

injury or death. Do not block suction.

CONTROLLED COPY approved for factory use on 4/16/2020.  RAYPAK PROPRIETARY AND CONFIDENTIAL INFORMATION .  Approval signatures on file in Engineering.

Summary of Contents for Raypak RPAGP100

Page 1: ...d experienced in the installation and maintenance of this type of equipment and related system components Installation and service personnel are required by some states to be licensed Persons not qual...

Page 2: ...ion to these Terms 3 2 IMPORTANT SAFETY INSTRUCTIONS 5 Entrapment Prevention 5 3 OVERVIEW 6 Constant Speed Pump Models 6 Dual Speed Pump Models 6 4 INSTALLATION 6 Pump 6 5 START UP 8 6 GENERAL MAINTEN...

Page 3: ...well as disinfectant feed ratios A AWARNING DO NOT increase pump size this will increase the flow rate through the system and exceed the maximum flow rate stated on the drain cover A AWARNING Before i...

Page 4: ...interrupter GFCI should always be installed at the power supply source of this unit Article 681 31 of the NEC requires that a GFCI be used if this pump is used with a storage pool Be sure to ground t...

Page 5: ...drains from the pump The system shall be constructed so that it shall not allow for separate or independent shutoff or isolation of each drain More than one pump can be connected to a single suction...

Page 6: ...pump is used with a storage pool Be sure to ground the motor before connecting it to an electrical AC power source Failure to ground the motor can cause serious or fatal electrical shock hazard DO NO...

Page 7: ...RPAGP100 0 75kW 1 0 Single RPAGP102 0 75kW Max 1 0 Dual RPAGP150 1 1kW 1 5 Single RPAGP152 1 1kW Max 1 5 Dual DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this...

Page 8: ...pressure from the system before proceeding 2 Unscrew the trap lid pre filter lid by turning counterclockwise 3 Remove the strainer basket and clean it Be sure all holes in the basket are unclogged th...

Page 9: ...tion or discharge line is partly closed Open or replace the valve Suction or discharge line is partly plugged Clear the obstruction Suction or discharge line is too small Re plumb use a larger pipe di...