7
• Before installing the pump, make sure that the
surface is solid, elevated, rigid and vibration free.
• Secure the pump to the base with screws or bolts
to limit the vibration and the stress on the pipes and
joints.
• Leave enough space for the isolation and check
valves on the suction and discharge piping, as
required.
• Connect the suction and discharge pipes to the outlet
and inlet of the swimming pool.
• Make sure that ground level drainage is adequate so
as to prevent flooding.
Model
Input power
Power (HP)
Speed
Voltage
Connection
Size
RPAGP75
0.55kW
0.75
Single
115V/60Hz
1.5”
RPAGP100
0.75kW
1.0
Single
RPAGP102
0.75kW(Max)
1.0
Dual
RPAGP150
1.1kW
1.5
Single
RPAGP152
1.1kW(Max)
1.5
Dual
• DO NOT store or use gasoline or other flammable
vapors or liquids in the vicinity of this pump. DO NOT
store pool chemicals near the pump.
• DO NOT remove any safety alert labels such as
DANGER, WARNING, or CAUTION. Keep safety
labels in good condition and replace any missing or
damaged labels.
• Make sure that the pump and piping are accessible
for servicing.
NOTE:
The pump suction and discharge connections
have molded-in thread stops. DO NOT try to screw pipes
beyond these stops.
Table A. Specifications
24.4" (620 mm)
10.8"
(274 mm)
6.3" (160 mm)
Figure 2. Dimensions
CONTROLLED COPY approved for factory use on 4/16/2020. RAYPAK PROPRIETARY AND CONFIDENTIAL INFORMATION . Approval signatures on file in Engineering.