NA3424 – In-line Automatic 9-lb Chlorine Feeder 

 for Above Ground Pools

 

 

 

 

 

 

 

 

INSTALLATION AND OPERATING INSTRUCTION

 

YOUR AUTOMATIC CHLORINE FEEDER 

is designed for installation in the return line (PCF03) to your pool or next to (PCF04) 

your filter 

system. When next to your filter system, it operates by the pressure differential of the system, which draws water through 

the feeder. It uses slow dissolve Trichloro-S-Triazinetrione (Tri-Chlor) large or small tablets (or sticks) ONLY. No other type of chemicals 

should ever be used in your chlorine feeder. Your automatic chlorine feeder holds up to 18 large (3") tablets (about 9-lbs) and has a dial 

type control valve to regulate the rate of water flow through the chlorine feeder. This large capacity feature, under normal conditions, 

should provide a minimum of two weeks chlorination for large pools. By regulating the valve setting between 

FULL 

(more chlorine) and 

OFF 

(no chlorine) and the amount of Tri-Chlor tablets you place in the feeder, you can easily adjust the chlorine feed rate that is 

necessary to maintain the proper chlorine residual for your pool. 

 

CAUTION - READ CAREFULLY

 

This chlorine feeder is designed to use Trichloro-S-Triazinetrione tablets - slow dissolving type. NEVER MIX with other types of chlorine or 

chemicals. Explosion or fire may result. Exercise extreme caution when opening or servicing your feeder. Always shut off pump and 

available valves before opening. Do not inhale fumes from any chemical feeder or container. Protect your eyes, skin and clothing from 

chemicals at all times. NEVER open chlorinator when pump is running. To prevent build up gas in chlorine feeder, be sure pool return line 

valve(s) is kept open - except when opening/servicing unit. Always read label and carefully follow chlorine manufacturer's and dealer's 

recommendations for proper water conditioning and daily chlorine requirements for your particular pool and area. 

 

DIRECTIONS FOR USE

 

Before start-up of your chlorine feeder, your pool/spa should be properly conditioned and have a chlorine residual of approximately 1.1 

to 1.5ppm.Follow dealer and chemical manufacturer's directions and instructions. The chlorine demand for pools and spas varies based 

on use, temperature, sunlight etc. Initially, you will have to experiment to determine the proper amount of chlorine and the correct valve 

setting required for your pool and filter time cycle. Using a 20,000 gallon pool as a guide, we suggest you place about 8 large, slow 

dissolving Tri-Chlor tablets (or about 4-lbs of small slow dissolve tablets or sticks) in your feeder and place the dial valve setting at #3. 

(Reduce or increase the amount of chlorine according to pool size, i.e., 30,000 gallon - add 50% more tablets) Check chlorine residual 

daily and adjust dial valve for more or less chlorine.  Increasing the quantity of chlorine in your feeder will extend the time between 

exchanging your feeder with more chlorine. 

 

EASY-LOCK COVER

 

To open:

 

1.

 

Shut off pump and turn DIAL CONTROL VALVE to OFF. Shut off any other in-line valves to prevent back flow; if applicable. Wait one minute. 

2.

 

Turn the LID counter-clockwise to open. 

Caution: do not inhale fumes from chlorine feeder.

 

To close: 

1.

 

Press the LID, with O-ring seal, firmly onto BODY. Engage the LID threads and turn clockwise to stop lug. 

2.

 

Place DIAL CONTROL VALVE to desired setting, open In-line valves and re-start pump. 

 

INSTALLATION OF PCF03 (IN-LINE) 

 

1.

 

Your automatic chlorine feeder is for permanent installation in the pool water return line. 

2.

 

Always install chlorine feeder after the heater. If there is no heater, install after the filter. Damage to the heater or filter may result if 

concentrated chlorine is allowed to flow through them. 

3.

 

Your automatic chlorine feeder is furnished with 1 ½” female threads. Socket adapters may also be used. Use pipe thread sealants 

formulated and approved for the use with plastic connections.  Do not over tighten. 

4.

 

The preferred installation is above water level and located in line below filter or heater outlets. An in- line positive seal corrosion resistant 

check valve should be installed to reduce backflow of chlorine gas when the system is shut off. If the chlorine feeder must be located 

below water level, provide check valve to prevent water backflow when opening/servicing the unit. 