Error Code 31, 32, 33 & 34
Thermistor fault.
Error Code 31, 32, 33, 34
Is the resistance of the
relevant* thermistor normal?
TEST 15
Replace relevant thermistor.
NO
Reinsert connector into
terminal P and retry operation.
NO
* Thermistor error codes:
31 = Water inlet thermistor
32 = Heat exchanger thermistor
33 = Hot water outlet thermistor
34 = Ambient air thermistor
YES
YES
Is the wiring between control
PCB and thermistor intact?
Is the thermistor multi-pin
connector fully inserted into
terminal P on control PCB?
YES
Replace control PCB.
Rectify wiring.
NO
Error Code 35
Improper Thermistor Connections.
Error Code 35
Is the cold and hot water
pipework to the water heater
reversed?
Reconfigure plumbing to the
water heater.
YES
Relocate thermistor positions.
NO
Is each thermistor fitted in its
correct position?
NO
Each thermistor connector is
colour coded. Is each
connector correctly fitted?
Rectify thermistor connections.
Replace control PCB.
NO
YES
YES