8
REGULAR CARE
MINOR SIX MONTH MAINTENANCE
It is recommended minor maintenance be performed every six months by a responsible officer.
The minor maintenance includes:
Operate the easing lever on the temperature pressure relief valve. It is very important you raise and
lower the lever gently. Refer to
“Temperature Pressure Relief Valve”
on page 10.
Warning:
Exercise care to avoid any splashing of water, as water discharged from the drain line will
be hot. Stand clear of the drain line‟s point of discharge when operating the valve‟s lever.
Operate the easing lever on the expansion control valve (if fitted). It is very important you raise and
lower the lever gently. Refer to
“Expansion Control Valve”
on page 9.
Check the drain line from the safe tray (if one is installed) is not blocked.
ANNUAL SERVICE
For safe and efficient operation, it is recommended an annual service be conducted on the water heater.
Warning
: Servicing of a water heater must only be carried out by qualified personnel. Phone Rheem
Service or their nearest Accredited Service Agent.
Note:
The annual service and routine replacement of any components, if required, are not included in the
Rheem warranty. A charge will be made for this work. Only genuine replacement parts should be used on
this water heater.
The annual service includes the following actions:
Inspect and flush the temperature pressure relief valve.
Inspect and flush the expansion control valve (if fitted).
Check and if necessary adjust the inlet gas pressure.
Check the piezo igniter, gas control and thermocouple.
Check the operation of and clean the pilot light and main burner.
Visually check the unit for any potential problems.
Inspect all connections.
Check the drain line from the safe tray (if one is installed) is not blocked.
Note:
The water heater may need to be drained during this service. After the completion of the service, the
water heater will take some time to reheat the water. Hot water may not be available for a while.
Summary of Contents for 260 Litre