Synchronous Motors MKD
MKD090
9-11
DOK-MOTOR*-MKD*******-PR07-EN-P Version7.0 19.05.2004
9.6 Blower
Units
MKD motors can also be delivered with optional blower units. Please
refer to the „Surface“ column of the data sheets for performance data of
surface-cooled motors. The mechanical dimensions of the blower unitis
are represented in the dimension drawings. The possibilities of
combining motor and blower unit and the technical data of the blowers
are represented in the table below.
Motor
Ordering name of blower unit
LEMH-
RB090B1XX
LEMH-
RB090B2XX
MKD090B
x
x
Technical data of blower unit
Description
Symbol
Unit
Type of cooling
radial
axial
Rated voltage
U
n
V
230V,
±
15%
50 / 60Hz
115V,
±
10%
50 / 60Hz
Rated power
P
n
W
45 / 39
41 / 38
Rated current
I
A
0,20 / 0,17
0,36 / 0,33
Not
Not
Mean air volume
V
m³/h
325 / 380
325 / 380
available
available
Blower unit mass
m
L
kg
1,2
1,1
Noise level
dB(A)
48 / 52
48 / 52
Air flow
B
A
blowing
--- Blower installation not possible; x Blower installation possible
Fig. 9-12: Technical data of MKD090 blower unit (optional)
Summary of Contents for MKD025A-144
Page 60: ...7 10 MKD041 Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 72: ...8 12 MKD071 Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 84: ...9 12 MKD090 Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 108: ...11 4 Accessories Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P Notes...
Page 118: ...12 10 Connection System Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 138: ...14 4 Handling Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 155: ...Synchronous Motors MKD Appendix 17 1 DOK MOTOR MKD PR07 EN P Version7 0 19 05 2004 17 Appendix...
Page 172: ...17 18 Appendix Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 183: ......