Vibration and Shock Loads
MKD motors can carry loads, such as are typically occurring in case of
presses, punches, or press inlets, only if they are attached in a shock-
absorbed or shock-decoupled way. The construction of such
attachments must be checked in isolated cases.
According to IEC 721-3-3 ed. 1987 and EN 60721-3-3 ed. 06/1994, MKD
motors, if used stationary and weather-resistant, may be operated under
the following conditions:
•
Longitudinal motor axis:
according to class 3M1
•
Transverse motor axis:
according to class 3M4
⇒
Ensure that the limits specified in Fig. 13-2 and Fig. 13-3 for storage,
transport, and operation of the MKD motors are not exceeded.
Influencing quantity
Unit
Maximum value
in longitudinal
axis
Maximum value
in transverse
axis
Amplitude of the excursion at 2
to 9 Hz
mm
0,3
3,0
Amplitude of the acceleration at
9 to 200 Hz
m/s²
1
10
Fig. 13-2: Limits for sinusoidal vibrations
Influencing quantity
Unit
Maximum value
in longitudinal
axis
Maximum value
in transverse
axis
Total shock-response spectrum
(according to IEC721-1, :1990;
Table 1, Section 6)
Type L
type I
Peak acceleration
m/s²
40
100
Fig. 13-3: Limits for shock load
Note:
MHD motors have higher maximum values.
Note:
Motors with attached blowers are
not suitable
for
applications subjected to shock loads, such as are occurring
in case of
•
punches,
•
presses,
or
•
loading
portals.
In such cases, motors without surface-cooling and a higher
torque must be used.
Summary of Contents for MKD025A-144
Page 60: ...7 10 MKD041 Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 72: ...8 12 MKD071 Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 84: ...9 12 MKD090 Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 108: ...11 4 Accessories Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P Notes...
Page 118: ...12 10 Connection System Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 138: ...14 4 Handling Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 155: ...Synchronous Motors MKD Appendix 17 1 DOK MOTOR MKD PR07 EN P Version7 0 19 05 2004 17 Appendix...
Page 172: ...17 18 Appendix Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 183: ......