Synchronous Motors MKD
Application Instructions
13-1
DOK-MOTOR*-MKD*******-PR07-EN-P Version7.0 19.05.2004
13 Application
Instructions
13.1 Operating Conditions
Setup Height and Ambient Temperature
The performance data specified for the motors apply in case of the
following conditions:
•
Ambient Temperature of
0 ºC up to +45 ºC
•
Setup Height
0 m up to 1000 m above MSL.
If you intend to use motors above these ranges, you must take the
“utilization factors” into consideration. This reduces the performance
data.
t
A
[°C]
1000
3000
2000
0,6
0,8
1
40
45
50
55
0
f
H
h
[m]
0,6
0,8
1
0,4
0,4
f
T
T100
T60
1000
3000
1
2
f
T
t
A
[°C]
0,6
0,8
1
40
45
50
55
0
f
H
0,4
0,6
0,8
1
0,4
ambientMHD.fh7
(1):
Utilization depending on the ambient temperature
(2):
Utilization depending on the setup height
f
T
:
Temperature utilization factor
t
A
:
Ambient temperature in degrees Celsius
∆
T60 /
∆
T100: Mode of operation
f
H
:
Height utilization factor
h:
Setup height in meters
Fig. 13-1: MKD derating (utilization factors)
If
either
the ambient temperature
or
the setup height is exceeding the
nominal data:
1. Multiply the torque data specified in the selection data by the
utilization factor.
2. Ensure that the reduced torque data are not exceeded by your
application.
If
both
the ambient temperature
and
the setup height are exceeding the
nominal data:
1. Multiply the determined utilization factors f
T
and f
H
by each other.
2. Multiply the value obtained by the motor torque data specified in the
selection data.
3. Ensure that the reduced torque data are not exceeded by your
application.
Nominal data
Exceeding the nominal data
Derating curves
Summary of Contents for MKD025A-144
Page 60: ...7 10 MKD041 Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 72: ...8 12 MKD071 Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 84: ...9 12 MKD090 Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 108: ...11 4 Accessories Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P Notes...
Page 118: ...12 10 Connection System Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 138: ...14 4 Handling Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 155: ...Synchronous Motors MKD Appendix 17 1 DOK MOTOR MKD PR07 EN P Version7 0 19 05 2004 17 Appendix...
Page 172: ...17 18 Appendix Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 183: ......