Synchronous Motors MKD
MKD090
9-1
DOK-MOTOR*-MKD*******-PR07-EN-P Version7.0 19.05.2004
9 MKD090
9.1 Technical
Data
Description
Symbol
Unit
MKD090B-035
Cooling mode –
Natural
Natural
Surface
Motor overtemperature
60K
100K
60K /100K
Electric parameters
Characteristic motor speed
n
K
min
-1
2500
Continous torque at standstill
M
dN
Nm
12,0
13,5
18,0
Continous current at standstill
I
dN
A
11,0
12,5
16,5
Peak current
I
max
A
49,5
Torque constant at 20°C
1
)
K
m
Nm/A
1,22
Voltage constant at 20°C
K
E(eff)
V/1000min
-1
111
Winding resistance at 20°C
R
12
Ω
1,88
Winding inductace
L
12
mH
15,5
Number of pole pairs
p
4
Rated data
2
)
Rated speed
n
N
min
-1
3000
3000
3000
Rated torque
M
N
Nm
7,2
10,2
15
Rated current
I
N
A
4,7
6,7
9,7
Rated power
P
N
kW
2,8
4
5,9
Rated voltage
U
N
V
354
369
399
Rated frequency
f
N
Hz
200
200
200
Mechanical parameters
Rotor inertia
J
M
kgm²
43,0 x 10
-4
Theoretical maximum torque
M
max
Nm
43,5
Minimum strand cross-sectíon
4
)
S
mm
2
1
1
1
Thermal time constant
T
th
min
60
60
30
Maximum speed
n
max
min
-1
5000
Motor mass
3
)
5
)
m
kg
14,0
Perm. storage and transport temp.
T
L
°C
-20 to +80
Permissible ambient temperature
6
)
T
um
°C
0 to 40
Max. setup height
6
)
h
m
1000 above NN
Protection category
7
)
IP65
Insulation class (according to DIN VDE 0530 Part 1)
F
Housing coat
Prime coat black in a/w RAL 9005
1
)
2
)
3
)
4
)
5
)
6
)
7
)
K
m
is to be used for calculations with crest values (I
dN
, I
max
). For calculations with root-mean-square values (rated data), the torque
constant K
m
must be multiplied by a factor of
2
.
Values determined according to EN 60034-1. Current and voltage specified as root-mean-square values.
Use the declared value in bracket for motors holding brake.
Applicable to REXROTH cables. Rated according to VDE0298-4 (1992) and installation type B2 according to EN 60204-1 (1993) at
an ambient temperature of 40 °C.
Without blower unit.
If the limits specified are exceeded, the performance data must be reduced if necessary. For reduction factors, refer to the chapter
entitled “Environmental Conditions”.
Provided the power and encoder cables are mounted properly
Fig. 9-1: Technical data MKD090B-035
Summary of Contents for MKD025A-144
Page 60: ...7 10 MKD041 Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 72: ...8 12 MKD071 Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 84: ...9 12 MKD090 Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 108: ...11 4 Accessories Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P Notes...
Page 118: ...12 10 Connection System Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 138: ...14 4 Handling Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 155: ...Synchronous Motors MKD Appendix 17 1 DOK MOTOR MKD PR07 EN P Version7 0 19 05 2004 17 Appendix...
Page 172: ...17 18 Appendix Synchronous Motors MKD 19 05 2004 Version7 0 DOK MOTOR MKD PR07 EN P...
Page 183: ......