background image

4

6

5

1

2

3

I

0

7

6

/16 

Bosch Rexroth AG   

Hydraulics

245LEN0040 - 0400; 245LE0130, 0150   RE 51421/07.11

The 245LE(N) inline filters are suitable for direct installation 
into pressure lines. They are mostly installed upstream open-
loop or closed-loop control units to be protected.
They basically consist of filter head (1), a screwable filter 
bowl (2), filter element (3) as well as mechanical optical main-
tenance indicator (4). In case of filters with low-pressure-dif-
ferential-stable filter elements (= code letter pressure differen-
tial A), there is also an assembled bypass valve (5).
Via port I, the hydraulic fluid reaches the filter element (3) 
where it is cleaned. The dirt particles filtered out settle in the 
filter bowl (2) and in the filter element (3). Via port 0, the fil-
tered hydraulic fluid enters the hydraulic circuit. 
The filter housing and all connection elements are designed 
so that pressure peaks - as they may e.g. occur in case of the 
abrupt opening of large control valves due to the accelerated 
fluid weight - can be securely absorbed. As of size 0160, the 
standard equipment comprises an oil drain plug (7).
Basically, the filter is equipped with mechanical optical main-
tenance indicator (4). The electronic maintenance indicator 
is connected via the electronic switching element with 1 or 2 
switching points (6), which has to be ordered separately. The 
electronic switching element is attached to the mechanical opti-
cal maintenance indicator and held by means of a locking ring.

Function, section

Summary of Contents for 245LE0130

Page 1: ...sistance of the filter elements e g in case of cold start Filter ratings of 3 m to 100 m By default equipped with mechanical optical maintenance indicator with memory function Flow optimized design du...

Page 2: ...G1 x x R5 G1 1 4 x R6 G1 1 2 x S6 SAE 1 1 2 x SAE flange 6000 psi U3 SAE 10 x Pipe thread according to SAE J1926 U4 SAE 12 x U5 SAE 20 x U6 SAE 24 x Standard connection x Additional connection possib...

Page 3: ...ilter Material no Replacement element 245LEN0040 H6XLA00 V5 0 M 30 6 6 R2 R928030280 U3 R928030472 R928006646 245LEN0063 H6XLA00 V5 0 M 52 11 4 R4 R928030281 U4 R928030473 R928006700 245LEN0100 H6XLA0...

Page 4: ...Line cross section 4 x 0 34 mm2 Core marking 1 2 3 4 Brown White Blue Black Material no R900064381 for electronic switching element with round plug in connection M12x1 For more round plug in connectio...

Page 5: ...green Circuit diagram drawn in plugged condition at temp 30 C op mode 30 C 20 C 86 F 68 F on off WE 2SPSU M12x1 WE 2SP M12x1 Switching element Connector Switching point 100 LED red Switching point 75...

Page 6: ...leaned The dirt particles filtered out settle in the filter bowl 2 and in the filter element 3 Via port 0 the fil tered hydraulic fluid enters the hydraulic circuit The filter housing and all connecti...

Page 7: ...Pressure differential Response pressure of the maintenance indicator bar psi 5 0 5 72 7 electrical electronic switching element Electrical connection Round plug in connection M12x1 4 pin Standard conn...

Page 8: ...3 10 8 17 13 10 admissible pressure differential A bar psi 30 435 B bar psi 330 4785 Seal material for hydraulic fluids Mineral oil Ordering code Mineral oil HLP according to DIN 51524 M Flame resista...

Page 9: ...Characteristic curves measured with HLP46 according to ISO 3968 H3XL A proper filter design is enabled by our computer program BRFilterSelect Oil viscosity Specific weight 0 9 kg dm3 p Q characterist...

Page 10: ...S 142 SUS Characteristic curves measured with HLP46 according to ISO 3968 H3XL H10XL A proper filter design is enabled by our computer program BRFilterSelect Oil viscosity Specific weight 0 9 kg dm3 p...

Page 11: ...SUS 315 SUS 142 SUS Characteristic curves measured with HLP46 according to ISO 3968 H10XL A proper filter design is enabled by our computer program BRFilterSelect Oil viscosity Specific weight 0 9 kg...

Page 12: ...245 LE N Content in l US gal A1 A2 A3 1 A4 A5 A6 B1 2 B2 B3 B4 B5 B7 C1 Stan dard U SAE J1926 0040 0 21 0 06 200 7 87 94 3 70 120 4 72 156 6 14 25 0 98 146 5 75 92 3 62 60 2 36 25 0 98 85 3 35 55 2 17...

Page 13: ...l optical maintenance indicator max tighten ing torque MA max 50 Nm 36 88 lb ft 2 Switching element with locking ring for electrical mainte nance indicator rotatable by 360 round plug in connection M1...

Page 14: ...0040 0100 N0040 0100 NG0130 0150 0130 0150 NG0160 0400 N0160 0400 Seal M NBR seal V FKM seal Seal kit D 245LE Seal kit Material no D245LEN0040 0100 M R928028016 D245LE0130 0150 M R928028214 D245LEN016...

Page 15: ...output via the switching element Only push the red pushbutton in again after the operating tem perature has been reached If it jumps out again immedi ately or if the electrical signal has not gone ou...

Page 16: ...rding to 51448 are pressure holding equipment according to article 1 sec tion 2 1 4 of the pressure equipment directive 97 23 EC PED However on the basis of the exception in article 1 section 3 6 of t...

Reviews: