Standard types

1)

 Measured pressure differential across filter and measuring 

equipment according to ISO 3968. The measured pressure 
differential at the maintenance indicator is lower.

245LE(N) standard types, NBR seal, flow information for 

ν

 = 30 mm²/s 

[150 SUS]

Inline filter with bypass, filtration rating 3 μm

Type

Flow in l/min 

[gpm]

with 

Δ

p

 = 1 bar 

[14.5 psi] 

1)

Material no.

Filter

Material no.

Replacement 

element

245LEN0040-H3XLA00-V5,0-M-..

23 

[5.1]

..R2

R928030024

..U3

R928030216

R928006645

245LEN0063-H3XLA00-V5,0-M-..

30 

[6.6]

..R4

R928030025

..U4

R928030217

R928006699

245LEN0100-H3XLA00-V5,0-M-..

44 

[9.7]

..R4

R928030026

..U4

R928030218

R928006753

245LE0130-H3XLA00-V5,0-M-..

74 

[16.3]

..R5

R928030027

..U5

R928030219

R928022274

245LE0150-H3XLA00-V5,0-M-..

89 

[19.6]

..R5

R928030028

..U5

R928030220

R928022283

245LEN0160-H3XLA00-V5,0-M-..

132 

[29.0]

..R6

R928030029

..U6

R928030221

R928006807

245LEN0250-H3XLA00-V5,0-M-..

190 

[41.8]

..R6

R928030030

..U6

R928030222

R928006861

245LEN0400-H3XLA00-V5,0-M-..

250 

[55.0]

..R6

R928030031

..U6

R928030223

R928006915

Inline filter with bypass, filtration rating 6 μm

Type

Flow in l/min 

[gpm]

with 

Δ

p

 = 1 bar 

[14.5 psi] 

1)

Material no.

Filter

Material no.

Replacement 

element

245LEN0040-H6XLA00-V5,0-M-..

30 

[6.6]

..R2

R928030280

..U3

R928030472

R928006646

245LEN0063-H6XLA00-V5,0-M-..

52 

[11.4]

..R4

R928030281

..U4

R928030473

R928006700

245LEN0100-H6XLA00-V5,0-M-..

61 

[13.4]

..R4

R928030282

..U4

R928030474

R928006754

245LE0130-H6XLA00-V5,0-M-..

101 

[22.2]

..R5

R928030283

..U5

R928030475

R928022275

245LE0150-H6XLA00-V5,0-M-..

120 

[26.4]

..R5

R928030284

..U5

R928030476

R928022284

245LEN0160-H6XLA00-V5,0-M-..

172 

[37.8]

..R6

R928030285

..U6

R928030477

R928006808

245LEN0250-H6XLA00-V5,0-M-..

226 

[49.7]

..R6

R928030286

..U6

R928030478

R928006862

245LEN0400-H6XLA00-V5,0-M-..

276 

[60.7]

..R6

R928030287

..U6

R928030479

R928006916

Inline filter with bypass, filtration rating 10 μm

Type

Flow in l/min 

[gpm]

with 

Δ

p

 = 1 bar 

[14.5 psi] 

1)

Material no.

Filter

Material no.

Replacement 

element

245LEN0040-H10XLA00-V5,0-M-..

36 

[7.9]

..R2

R928030536

..U3

R928030728

R928006647

245LEN0063-H10XLA00-V5,0-M-..

69 

[15.2]

..R4

R928030537

..U4

R928030729

R928006701

245LEN0100-H10XLA00-V5,0-M-..

75 

[16.5]

..R4

R928030538

..U4

R928030730

R928006755

245LE0130-H10XLA00-V5,0-M-..

127 

[27.9]

..R5

R928030539

..U5

R928030731

R928022276

245LE0150-H10XLA00-V5,0-M-..

150 

[33.0]

..R5

R928030540

..U5

R928030732

R928022285

245LEN0160-H10XLA00-V5,0-M-..

210 

[46.2]

..R6

R928030541

..U6

R928030733

R928006809

245LEN0250-H10XLA00-V5,0-M-..

260 

[57.2]

..R6

R928030542

..U6

R928030734

R928006863

245LEN0400-H10XLA00-V5,0-M-..

300 

[66.0]

..R6

R928030543

..U6

R928030735

R928006917

Summary of Contents for 245LE0130

Page 1: ...sistance of the filter elements e g in case of cold start Filter ratings of 3 m to 100 m By default equipped with mechanical optical maintenance indicator with memory function Flow optimized design du...

Page 2: ...G1 x x R5 G1 1 4 x R6 G1 1 2 x S6 SAE 1 1 2 x SAE flange 6000 psi U3 SAE 10 x Pipe thread according to SAE J1926 U4 SAE 12 x U5 SAE 20 x U6 SAE 24 x Standard connection x Additional connection possib...

Page 3: ...ilter Material no Replacement element 245LEN0040 H6XLA00 V5 0 M 30 6 6 R2 R928030280 U3 R928030472 R928006646 245LEN0063 H6XLA00 V5 0 M 52 11 4 R4 R928030281 U4 R928030473 R928006700 245LEN0100 H6XLA0...

Page 4: ...Line cross section 4 x 0 34 mm2 Core marking 1 2 3 4 Brown White Blue Black Material no R900064381 for electronic switching element with round plug in connection M12x1 For more round plug in connectio...

Page 5: ...green Circuit diagram drawn in plugged condition at temp 30 C op mode 30 C 20 C 86 F 68 F on off WE 2SPSU M12x1 WE 2SP M12x1 Switching element Connector Switching point 100 LED red Switching point 75...

Page 6: ...leaned The dirt particles filtered out settle in the filter bowl 2 and in the filter element 3 Via port 0 the fil tered hydraulic fluid enters the hydraulic circuit The filter housing and all connecti...

Page 7: ...Pressure differential Response pressure of the maintenance indicator bar psi 5 0 5 72 7 electrical electronic switching element Electrical connection Round plug in connection M12x1 4 pin Standard conn...

Page 8: ...3 10 8 17 13 10 admissible pressure differential A bar psi 30 435 B bar psi 330 4785 Seal material for hydraulic fluids Mineral oil Ordering code Mineral oil HLP according to DIN 51524 M Flame resista...

Page 9: ...Characteristic curves measured with HLP46 according to ISO 3968 H3XL A proper filter design is enabled by our computer program BRFilterSelect Oil viscosity Specific weight 0 9 kg dm3 p Q characterist...

Page 10: ...S 142 SUS Characteristic curves measured with HLP46 according to ISO 3968 H3XL H10XL A proper filter design is enabled by our computer program BRFilterSelect Oil viscosity Specific weight 0 9 kg dm3 p...

Page 11: ...SUS 315 SUS 142 SUS Characteristic curves measured with HLP46 according to ISO 3968 H10XL A proper filter design is enabled by our computer program BRFilterSelect Oil viscosity Specific weight 0 9 kg...

Page 12: ...245 LE N Content in l US gal A1 A2 A3 1 A4 A5 A6 B1 2 B2 B3 B4 B5 B7 C1 Stan dard U SAE J1926 0040 0 21 0 06 200 7 87 94 3 70 120 4 72 156 6 14 25 0 98 146 5 75 92 3 62 60 2 36 25 0 98 85 3 35 55 2 17...

Page 13: ...l optical maintenance indicator max tighten ing torque MA max 50 Nm 36 88 lb ft 2 Switching element with locking ring for electrical mainte nance indicator rotatable by 360 round plug in connection M1...

Page 14: ...0040 0100 N0040 0100 NG0130 0150 0130 0150 NG0160 0400 N0160 0400 Seal M NBR seal V FKM seal Seal kit D 245LE Seal kit Material no D245LEN0040 0100 M R928028016 D245LE0130 0150 M R928028214 D245LEN016...

Page 15: ...output via the switching element Only push the red pushbutton in again after the operating tem perature has been reached If it jumps out again immedi ately or if the electrical signal has not gone ou...

Page 16: ...rding to 51448 are pressure holding equipment according to article 1 sec tion 2 1 4 of the pressure equipment directive 97 23 EC PED However on the basis of the exception in article 1 section 3 6 of t...