Revv Dynamis 40w Continuous Controller Commands (CC)
In order to use CC commands, the Dynamis Functions have all been
given a designated number & on or off setting. When using & selecting a
function the number associated with the function must be used & then
the setting of the function (on or off) must also be sent. Most MIDI equip-
ment (pedals etc) allows you to select a CC number & then designate
whether it be turned to on or off. (Consult the external equipments’
instruction manual). The following commands & their CC numbers need
only be sent an on command (0-63) as they are used to switch between
channels & dynamic levels which cannot be turned off, only changed to
a different channel or level, on & off commands sent will produce the
same result.
Fu CC Number (Hex Value)
Channel 1 Clean - 16 - (0×10)
Channel 2 low dynamic level - 18 - (0×12)
Channel 2 medium dynamic level - 19 - (0×13)
Channel 2 high dynamic level 20 - (0×14)
Decay short level 33 - (0×21)
Decay medium level 34 - (0×22)
Decay long level 35 - (0×23)
The following command will switch to channel 2 & then toggle through
the dynamic levels with each use of the command like using the
footswitch to switch to the channel & toggle through the dynamic levels.
This command will also respond to an on & off command with the same
result:
Channel two plus dynamic toggle: 24 – (0x18)