Revitive Medic 5573AQ User Manual Download Page 6

10

11

 Warnings

 

 

When applying foot-pads or electrode body pads:

•  There is a chance you may experience skin irritation or burns beneath the electrodes  
 

or hypersensitivity due to the electrical stimulation

•  Ensure that any moisturiser/gel/balm is evenly applied and thoroughly absorbed    
 

into the skin before applying stimulation. There is a chance that uneven application  

 

of a moisturiser/gel/balm could increase the risk of skin irritation or burn, when    

 

using the electrical stimulation

 

•  Symptoms may worsen during the initial treatment phase before getting better.    
 

This may occur if the body has not fully adjusted to increased muscular activity  

 

 

and blood circulation. If this occurs, reduce the intensity and the duration of  

 

 

treatment which will reduce the initial symptoms. If symptoms persist consult  

 

 

with your doctor

 

When not to use Revitive:

•  Do not use the device:

 

 

  In the presence of electronic monitoring equipment

 

  Together with a life-supporting medical electronic device

 

  When you are in the bath or shower

 

  While you are sleeping 

 

•  In conjunction with a brace or cast without first  consulting with your doctor

•  Use of this equipment adjacent to or stacked with other equipment should be  

 

 

avoided because it could result in improper operation. If such use is necessary,  

 

 

this equipment and the other equipment should be observed to verify that they    

 

are operating normally

 

Additional Warnings:

•  Use of accessories and cables other than those specified or provided by the  

 

 

manufacturer of this equipment could result in increased electromagnetic emissions  

 

or decreased electromagnetic immunity of this equipment and result in improper    

 operation.
•  Portable RF communications equipment (including peripherals such as antenna    
 

cables and external antennas) should be used no closer than 30 cm (12 inches)  

 

 

to any part of the Revitive System, including cables specified by the manufacturer

       

Important safeguards

 

Warnings

 

Consult with your doctor before using this device if:

•  You are in the care of a doctor
•  You have a history of heart problems 
•  You have had medical or physical treatment for your pain  
•  You have suspected or diagnosed heart disease
•  You have suspected or diagnosed epilepsy
•  You are unsure about the suitability of the device for you
•  You are unsure about the cause of your symptoms 
 

If you have a metallic implant:

•  If you have a metallic implant, you may experience pain or discomfort near  the  

 

  implant when applying electrical stimulation. If this should occur discontinue use    
  and seek advice from your doctor
•  The electrical stimulation may feel more intense close to a metallic implant. It is    
  safe to continue use provided no pain is experienced. You may need to adjust the    
  intensity to a comfortable level

When applying foot-pads or electrode body pads:

• Do 

not use the electrode pads on your head, face, neck or chest 

•  Application of the electrodes near the thorax (chest) may increase the risk of cardiac  
 

fibrillation  

• Do 

not apply foot-pads or electrode pads directly: 

 •

  on open wounds or rashes; swollen, red, infected or inflamed areas; or skin  

 

     eruptions (such as phlebitis, thrombophlebitis, varicose veins, cellulitis)  

 •

  on, or close to, malignant tumours  

 

 •

  on areas treated with radiotherapy (within the past 6 months) 

 •

  on reproductive organs 

 

  on opposing thighs and refer to pad placement diagrams in this User’s Manual for  

  

 correct 

placement

•  When using TENS do 

not apply to areas of skin that lack sensation

•  Electrode pads are for single person use only. Do 

not share Body Pads with  others 

• Do 

not use electrode pads after their use-by date

5603_IFU02_17807098.indd   10-11

5603_IFU02_17807098.indd   10-11

12/01/2021   08:53

12/01/2021   08:53

Summary of Contents for Medic 5573AQ

Page 1: ...this product USE ONLY AS DIRECTED If symptoms persist consult your healthcare professional Medic Drug Free Clinically Proven Certified Medical Device User s Manual CIRCULATION BOOSTER 5603_IFU02_1780...

Page 2: ...21 Step 4 Using the Dual Mode Body Pads 22 27 4 1 Switching between EMS and TENS mode 27 Step 5 Cleaning and storing 28 Replacing the batteries Body Pads 28 Troubleshooting 29 31 Technical Specificat...

Page 3: ...his booklet Power adapter Cable length 180cm Revitive Medic Electrode Body Pads Electrode cord Cable length 150cm Remote control AAA batteries x 2 1 2 3 4 5 6 Parts and controls 70 3o Carry handle Con...

Page 4: ...pads Revitive is intended to Reduce pain and discomfort in the legs ankles feet caused by poor circulation Peripheral Arterial Disease Improve circulation in the legs caused by Peripheral Arterial Dis...

Page 5: ...tor as soon as possible if you show any signs of the above symptoms Important safeguards Introduction to Revitive Electrical Muscle Stimulation EMS Indications for use continued When using electrode p...

Page 6: ...tenna cables and external antennas should be used no closer than 30 cm 12 inches to any part of the Revitive System including cables specified by the manufacturer Important safeguards Warnings Consult...

Page 7: ...operating temperatures to ensure continued product performance Cautions When applying foot pads or electrode body pads Be careful when applying stimulation over areas of skin that lack normal sensatio...

Page 8: ...elp identify the parts b Locate the remote control and insert the batteries Before you use Revitive for the first time read the Important Safeguards on pages 9 14 If in doubt consult your doctor befor...

Page 9: ...ry level If you turn the device off and the low battery level indicator blinks for 10 seconds the battery requires recharging Please note you can use the device while it is charging but the battery in...

Page 10: ...aveforms to your feet and legs You can use the Body Pads to receive EMS or TENS see pages 20 25 for details a It is important that you are well hydrated We recommend that you apply a moisturiser to th...

Page 11: ...arise yourself with the feeling of the Medic Program Use on a low intensity for 30 60 minutes once per day for a few days Set the intensity at a level where you can feel the stimulation in your feet w...

Page 12: ...provides you with strong but comfortable muscle contractions It is recommended to use Revitive in TENS mode for temporary pain relief from chronic joint muscular nerve or arthritic pain Use for 20 30...

Page 13: ...se the default time of 30 minutes set the time for the number of minutes you want You can use the controls on the control panel or on the remote control Press the Time Control to increase the time Pre...

Page 14: ...imulation You can set the intensity between 1 99 You can use the buttons on the device or remote control Press the button to increase the level Press the button to decrease the level It is normal to f...

Page 15: ...lectrode cord is plugged in Revitive may be in auto pause Ensure that you have drunk plenty of water and that your feet are well moisturised Place both feet onto the foot pads then press intensity but...

Page 16: ...rrectly If still not working contact your authorised dealer Flat battery Plug device in an electrical socket and charge battery or run using mains power option Revitive is not vibrating REVITIVE IS NO...

Page 17: ...e Rectangular Maximum Output Voltage 500 50V Pulse Duration 100 s Net Charge per pulse 500 0 C Maximum Average Power Density 500 4 19 mW cm2 Technical Specifications Name of product Revitive Medic Mod...

Page 18: ...C allow the product to re adjust to the recommended operating temperatures to ensure continued product performance Indoor Use Only Medical device does not contain natural rubber latex Do not disassem...

Page 19: ...to retain your original till receipt or invoice to indicate the date of initial purchase To qualify for the 2 year guarantee the device must have been used according to the manufacturer s instructions...

Page 20: ...DSS Schiffgraben 41 30175 Hannover Germany Copyright 2021 Actegy Ltd All rights reserved Actegy Revitive Revitive Medic Circulation Booster OxyWave IsoRocker and SoftTouch Pads are trademarks or regis...