In order for your device to preform perfectly it is
necessary to replace its consumables by following
periodicals (for all devices):
Cristalle is equipped with three (3) PreFilters in
following order:
-Push-In PolyPropylene 5 micron
-Push-In CTO or GAC (carbon pre-filter)
-Push-In PolyPropylene 1 micron
In order for your device to preform perfectly and to
avoid any malfunctions it is necessary to replace
consumables in periodicals stated by your local
distributor. In case these filters are left to preform
longer than stated by your local distributor, warranty
for whole device is automatically voided.
Cristalle is equipped with In-Line GAC (granular
activated carbon) PostFilter. In order for your device to
preform perfectly and to avoid any malfunctions as
well as hazard for human health (if post-filter used too
long) it is necessary to replace this consumable in
periodicals stated by your local distributor.
Cristalle is equipped with R.O. (reverse osmosis)
membrane. It is a main working part of device. Main
process of water purification is conducted by this
element. R.O. membrane is made to last longer period
of time, its life span greatly depends from feed water
quality. Due to changing water quality it is not possible
to determine this element’s exact usage period. Your
local AUTHORISED SERVICE PERSONNEL will conduct
tests during each maintenance and inform you when it
is needed to replace this element.
PREFILTERS:
POSTFILTER:
R.O. membrane:
Below, we provide approximate information on
replacing
R.O. membrane element for different
device configurations:
approximately once every two (2) years from the
moment of installation or last such maintenance.
approximately
once every three to four (3-4) years from the moment
of installation or last such maintenance. Devices with
diaphragm pump replace this element every 3-4 years
due to higher and constant pressure on R.O.
membrane. Additionally, device preforms Auto-Flush
operations every 6 hours what prologues R.O.
membrane life span.
Device is equipped with self-regulating diaphragm
pump which needs to be checked periodically on
pump performance. This test is made once a year and
performed
only
by
AUTHORISED
SERVICE
PERSONNEL.
Tank must remain at all times pressurized. Tank
pressure is checked at every maintenance only by
AUTHORISED SERVICE PERSONNEL. Once (1) per
year it is necessary to clean the tank. This work is
preformed
only
by
AUTHORISED
SERVICE
PERSONNEL.
All small parts used in device are being checked
during the maintenance. These checks are preformed
only by AUTHORISED SERVICE PERSONNEL. In case
replacement of any part is needed, you will be
informed upon. During warranty period small parts
are subject to free of charge replacement which is
preformed
only
by
AUTHORISED
SERVICE
PERSONNEL.
D E V I C E
W I T H O U T
D I A P H R A G M
P U M P:
DEVICE WITH DIAPHRAGM PUMP:
DIAPHRAGM PUMP:
TANK:
SMALL PARTS:
CONSUMABLES &