background image

R.O. membrane

R.O. device

PreFilter

PolyPropylene

In-Line PostFilter

Tank

Self-Adjusting Diaphragm Pump

High pressure switch

Low pressure switch

Solenoid

- Reverse Osmosis membrane. Main

filtration unit used to purify water. Works on principle
of reverse osmosis.

- Device which consists of several pre-

filters, R.O. membrane, post-filter, tank and faucet.
Configuration may vary from type of device.

- Every R.O. device consists of three (3) pre-

filters which are used to prepare water for main
purification, such prepared water is delivered to R.O.
membrane to start the purification process. Pre-filters
inside device have following specifications:
- 1st PreFilter: 5 micron PolyPropylene
- 2nd PreFilter: GAC (Granular Activated Carbon) or
CTO (Solid Carbon Block)
-3rd PreFilter: 1 micron PolyPropylene

- material used to manufacture fist

and third PreFilter.

- Filter which is placed after R.O.

membrane. Water from the tank flows through post-
filter just before it is released through faucet.

- Stainless steel or plastic tank which is used to

storage purified water. These tanks exist in several
sizes: 2.0G (7.56L), 2.2G (8.31L), 2.8G (10.58L), 3.2G
(12.09L), 3.8G (13,36L) (plastic tank), 4.0G (15.12L)
(plastic tank), 10G (37,80L), 20G (75,60L)

- Pump which is

installed before R.O. membrane. Its purpose is to
higher the pressure and amount of water delivered to
R.O. membrane. Pump helps to prolonge R.O.
membrane life span.

- Electrical mechanism

installed inside device which function is to stop the
device’s work when the tank is full.

- Electrical mechanism which is

installed before water enters PreFilters which function
is to detect presence of water. In case of low pressure
or lack of feed water device stops to function until
water returns or pressure has risen again.

- Electrical mechanism used to stop water

flow. Each R.O. device with pump has 2 solenoids. First
is used to stop the water entering device, second for
membrane Auto-Flushing.

- Automatic process on devices with

pump, occurring every 6 hours. Auto-Flush raises the
pressure in R.O. membrane housing for 30 seconds.
R.O. membrane is being cleaned this way. This
function prolongs R.O. membrane life span.

- Small electrical sensor placed at the

bottom of device which reacts to water presence by
stopping the device’s operation.

- This is first filter which comes in contact

with water. Its main function is not to allow particles
larger than 5 microns to pass through it. These
particles can be: dirt, sand, rust, microscopic particles
several times smaller than grain of sand.

- This filter only function is to reduce

elements that cause water to taste and smell
unpleasantly, including the taste and odor of chlorine
which is also very dangerous for R.O. membrane and
if present in larger amounts can damage R.O.
membrane in very short period of time.

- This filter is placed after 2nd PreFilter

and its function is not to allow particles larger than 1
micron to pass through it. Usually these are all smaller
particles which can influence with R.O. membrane life
span.

- Its average removal percentage

are as follows:

Auto-Flush

Anti-Leak

COMPONENTS CHARACTERISTICS:
1st PreFilter

2nd PreFilter

3rd PreFilter

R.O. membrane

Alu%,

N%,

Amm%,

N i t r a t e 9 3 + % ,

A r s e n i c 9 4 + % ,

P h o s p h a t e 9 9 + % ,

Bac%, Polyphos%, Bicarb%,
Po t a s s i u m 9 2 + % ,

B r o m i d e 9 3 + % ,

P y r o g e n 9 9 + % ,

Cadmium98%,

Radioact%,

Ca%,

R a d i u m 9 7 + % ,

C h l o r i d e 9 4 + % ,

S e l e n i u m 9 7 % ,

Chromate98%, S%, Chr%, Sil%,
Copper99%, S%, Cy%, S%,
Ferrocyanide99%, Sul%, Flouride94-96%,
Sul%, %, %, %,
V i r u s 9 9 + % ,

M a g n e s i u m 9 6 + % ,

I n s e c t i c i d e s 9 7 % ,

Mang%, Detergents97%, Mercury 96+%,
Herbicides97%, TDS 95+%.

EXPLANATION OF TERMINOLOGY:

Summary of Contents for RO-CRISTALLE

Page 1: ......

Page 2: ...er Warnings Before unit startup Box contents Using the device Consumables replacing maintenance periodicals Terminology and components characteristics Limited warranty Owner Device information Warranty Confirmation 3 4 5 7 8 9 10 11 12 15 ...

Page 3: ... it the most advanced product in the world The Reverse Osmosis water treatment method is regarded as one of the most efficient and effective way to remove all viruses bacteria impurities and mechanical dirt from water Here are some of the advantages of your newly acquired device With our device you can be assured that you will be drinking only crystal clear water Installation and set up will take ...

Page 4: ...ance OFF by plugging the cord out of the wall outlet use the appliance for other than intended household use 1 2 3 4 5 6 7 8 9 10 11 Check voltage to be sure that the voltage indicated on the nameplate agrees with your voltage Never use warm or hot water as a device supply Use cold water only Keep the cord away from hot parts this way you protect it from melting Never clean with scouring powders o...

Page 5: ...open flames 5 cm away from walls and cooking tops the device at a temperatures below 8 C frost will damage it must be reachable at all times use the device outdoors Preventing Injury Power Supply Do not leave packing material near children The device must be out of the reach of children Children are not aware of the risks involved with electrical and non electrical devices Connect the device to a ...

Page 6: ...ervice centers only genuine parts are not used or filters are not replaced by authorised service centers local distributors nor manufacturer are liable for any damages or water quality cleaning the device turn OFF the device then remove the plug from the wall outlet immerse the appliance in water Avoid splashes tamper with the machine inside parts 1 2 3 4 5 1 2 3 4 5 1 2 3 BEFORE INSTALLATION CHEC...

Page 7: ...RISTALLE AC Adapter Stainless Steel faucet RO Membrane Owner s Manual Feed Water Valve Drain Water Valve Tubes Your device s configuration may vary This list is made only for checking purposes For exact list of box contents please contact your local distributor ...

Page 8: ...s In this moment device will stop functioning and it is advised to contact AUTHORISED SERVICE CENTER No feed water Leak Very low feed water pressure Bad quality of feed water Pump failure Electronics failure In case of no feed water it is not necessary to contact your local AUTHORISED SERVICE CENTER Device will start again as soon as feed water becomes available we advise to close the device s fee...

Page 9: ...h maintenance and inform you when it is needed to replace this element PREFILTERS POSTFILTER R O membrane Below we provide approximate information on replacing R O membrane element for different device configurations approximately once every two 2 years from the moment of installation or last such maintenance approximately once every three to four 3 4 years from the moment of installation or last ...

Page 10: ...s risen again Electrical mechanism used to stop water flow Each R O device with pump has 2 solenoids First is used to stop the water entering device second for membrane Auto Flushing Automatic process on devices with pump occurring every 6 hours Auto Flush raises the pressure in R O membrane housing for 30 seconds R O membrane is being cleaned this way This function prolongs R O membrane life span...

Page 11: ...ifications is not covered by this warranty REMEDIES DISCLAIMER OF WARRANTY THE WARRANTIES EXPRESSLY SET FORTH IN THIS AGREEMENT REPLACE ALL OTHER WARRANTIES TO THE EXTENT PERMITTED BY LAW WE DISCLAIM ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE AND NONINFRINGEMENT OF THIRD PARTY RIGHTS WITH RESPECT TO THE R O DEVICE NO DEALER ...

Page 12: ...OWNER INFO name surname date installation date installation address device type DATE MAINTENANCE TYPE Membrane Pump Tank O t h e r P a r t s Signature ...

Page 13: ...DATE MAINTENANCE TYPE Membrane Pump Tank O t h e r P a r t s Signature ...

Page 14: ...DATE MAINTENANCE TYPE Membrane Pump Tank O t h e r P a r t s Signature ...

Page 15: ...ephone number Maintenance Center address This warranty is voided in case of no existence of distributor s stamp and signature If you received this manual without below entered information please contact your distributor and appoint signing and stamping this warranty ...

Page 16: ......

Reviews: