Temperature Shock Freezing
Select shock freezing by pressing
key: LED
,
,
and
blink. The display
shows the end cycle temperature. Using the and
keys the end shock freezing temperature (-18°C)
can be changed. Insert the core probe into the
product. To select the SOFT cycle press the key
. LED
will turn off.
Start the cycle by pressing key
. LED
,
and
are permanently on.
The test for the proper insertion of the probe will
start.
If the test gives a positive result, the blast chilling
cycle starts, in case of negative result the
machine will run a timed blast chilling (see proper
chapter).
During shock freezing the display shows the
temperature detected by the core probe.
By pressing the
key, temperature detected
by the chamber probe can be visualized.
If the product temperature reaches the
established value within the established time set
on parameter
r6
, the cycle is considered as
completed: a preserving cycle is automatically
started and an intermittent sound confirm the
correct conclusion of the cycle.
In case the product temperature does not reach
the established value within the maximum time
allowed, the cycle continue: LED
blinks
accompanied by an intermittent sound. To stop
the alarm press any key.
As soon as product temperature is lower than the
established value the shock freezing cycle is
considered as completed and a preserving cycle
is automatically started.
During preservation the display shows the
temperature detected by the chamber probe; LED
is switched on.
Press
to conclude the preservation cycle.
Time Shock Freezing
Select the freezing process pressing twice the
button
, the leds
,
,
and
blink. The display shows the time of the cycle.
Using the buttons
and
you can change
the time of freezing
To select a soft cycle, press the button
:
the LED
will turn off.
To start the cycle, press the button
:. The
leds,
,
and
remain lit steadily.
At the end of the setted time, the freezing cycle is
completed and automatically starts a cycle of
conservation.
During the storage phase the display shows the
temperature measured by the room probe, the
LED
is turned on.
Press the button
to end the cycle of
conservation.
1
3
2
1
3
2