12
ENGLISH
GB
Time Defrosting
Select defrosting by pressing
key twice:
LED
,
,
and
blink. The
display shows the cycle duration. By using the
and
keys, the freezing time can be
changed.
To select the SOFT cycle press the
key.
LED
will turn off.
Start the cycle by pressing key
. LED
,
and
are permanently on.
Once the set time is over, the shock freezing cycle
is considered as completed and a preserving
cycle is automatically started.
During preservation the display shows the
temperature detected by the chamber probe;
LED
is switched on.
Press
to conclude the preservation cycle.
Cooling Cycle
Select the cooling cycle by pressing for two
seconds
key: LED
blinks: a cooling
cycle will be started. The working set point is
established on parameter
r12
. When the chamber
temperature reaches the set value, the cycle
continue, LED
is permanently on
accompanied by a one second sound signal.
Defrosting
First make sure there is no preservation cycle
running. Press for at least four seconds key
:
LED
will be switched on.
Defrosting is performed by forced ventilation using
the evaporator fan. The cycle can be performed
with the door open or closed and can also be
interrupted at any time using
key.
1
1
3
2