22
ENGLISH
GB
8.2. Installation
All the installation phases must be considered,
from the moment of creation of the general plan.
The installation area must be equipped with all
power supply and production residue drainage
connections and must be suitably lit and respect
current laws regarding hygiene and sanitary
requirements.
The performance of the appliance is
guaranteed with a room temperature of 32°C. A
higher temperature can compromise its
performance and, in more serious cases, cause
the appliance’s protections to start up.
Therefore, consider the most critical room
conditions that can be reached in that position
before making a choice.
Level the appliance by acting on the individual
feet.
!
This appliance can only be installed and
operate in rooms which are permanently
ventilated, in order to guarantee correct operation.
Connect and leave for a certain period of
time (at least 2 hours) before checking
functioning. During transport it is probable that the
compressor lubricant oil has entered the
refrigerant circuit blocking the capillary: as a
consequence the appliance will function for a
certain period of time without producing cold until
the oil has returned to the compressor
.
!
ATTENTION:
the appliance requires the
minimum functioning spaces, as shown in the
attachments.
The defrosting water and the water that forms at
the bottom of the refrigerating compartment
during operation or during periodical internal
cleaning must be drained through a prearranged
hose with a minimum diameter 3/4” connected to
the hose at the bottom of the chiller.
A drain trap should also be guaranteed. The drain
must be in compliance with Standards in force.
8.3. Electric
Power Supply Connection
Connection must be carried out by authorised and
qualified staff, respecting the current laws
regarding the subject and using appropriate
prescribed material.
Before connecting the appliance to the
electric mains, check that the voltage and the
frequency correspond to the data stated on the
registration plate applied on the rear of the
appliance.
The appliance is supplied with an operating
voltage of 400V 3+N~ 50Hz. On request, it is
possible to have appliances with different
voltages.
!
Before connection, ensure the presence of a
relevant differential switch with adequate power in
the mains power supply, upstream from the
appliance, in order to protect the appliance from
overloads or short circuits