Ideal Placement

• 

Make sure the location you choose is as close to an air 

supply duct as possible and as far away from the HVAC air 

return duct as possible. This will ensure that the oxidizing 

molecules produced by the ReSPR FLEX are optimally 

circulated.

• 

Each ReSPR FLEX can effectively treat 3,000 sq feet of 

space as long as there is air circulation in the space. Be sure 

doors are open in areas that you wish to treat.

• 

To ensure the unit works properly, there should be as much 

space as possible in front of your ReSPR FLEX so that It 

can efficiently process the air in the area.

• 

Place ReSPR FLEX on a shelf or counter top. 

Never place an operating unit on the floor.

Operating ReSPR FLEX

1.  Connect the Power Cord to the Power Adapter and the 

Power Adapter Plug into the unit. (Check to be sure your 

power supply is properly assembled. The Power Cord should 

be inserted far enough into the Power Adapter so that a 

space of only about 1/8 in. is left between the widest part of 

the power cord and the edge of the Power Adapter).

2.  Insert the Power Plug into the wall outlet.
3.  Turn on the unit by pressing the POWER button and set 

it to NORMAL mode. The screen will read PCO (Photo 

Catalytic Oxidation) or NCC (Natural Catalytic Conversion). 

This is the optimal setting for running ReSPR FLEX 

continuously in your office or home. Adjust the fan to a 

comfortable sound level using the up and down buttons 

next to the display.

4.  ReSPR FLEX comes with a remote control and one lithium 

battery (CR20253V) for easier operation when the unit is 

placed on a high shelf.

Set up and Operation

(Initial Setup)

6

Summary of Contents for ReSPR FLEX

Page 1: ...www resprtech COM ReSPR FLEX Owner s Manual ReSPR Technologies...

Page 2: ...free service when it is properly maintained Even when properly cared for some parts of your ReSPR FLEX will need to be replaced periodically Replacement parts can be purchased from your authorized di...

Page 3: ...3 Quickstart 4 Warnings 5 Setup Operation 6 Diagrams 8 Routine Maintenance 12 Troubleshooting 15 Limited Warranty 17 Records Specifications 18 Contents ReSPR Technologies...

Page 4: ...in NORMAL Mode Screen will read PCO PhotoCatalytic Oxidation or NCC Natutal Catalytic Conversion This is the standard mode for occupied rooms HIGH mode for burst disinfection should not be used for mo...

Page 5: ...lled CAUTION Directly viewing the lamp inside unit for an extended period longer than 20 min may result in eye damage CAUTION Never adjust setting to exceed square footage of ventilated space being tr...

Page 6: ...onnect the Power Cord to the Power Adapter and the Power Adapter Plug into the unit Check to be sure your power supply is properly assembled The Power Cord should be inserted far enough into the Power...

Page 7: ...splay screen settings When to use AWAY Mode AWAY Mode generates ozone for deep cleaning an area This mode can be used for removing smoke cooking odors mold spores viruses and bacteria AWAY mode runs o...

Page 8: ...Needle 1 Front Grille 2 Control Panel 3 Rear Cover Screw 1 Rear Cover Grooves 2 Power Adapter Inlet 3 Rear Cover 1 Unit Rear 2 Unit Front 3 1 2 3 Front of Unit Rear of unit Side of Unit Diagrams Unit...

Page 9: ...1 NCC Cell Nuts 2 NCC Connector 3 Power Cord 1 Power Cord Plug 2 Power Adapter 3 Power Adapter Plug 4 Purification Plate 4 Rear of Unit Rear Cover Removed Rear of Unit Filter Assembly Removed Power S...

Page 10: ...Control 3 Sleep Mode Control 4 Fan Level Control 5 Away Mode Control 6 Diagrams Controls Remote Control Panel 10 1 2 4 5 3 Power Button 1 Fan Speed Control 2 3 4 5 Power Button 1 Fan Speed Control 2...

Page 11: ...ator 1 Mode Specific Display 2 Mode Indicator 3 Purification Level Warning 4 Maintenance Reminders 5 Away Mode Warning 6 Mode Specific Display Normal Technology Indicator NCC High Square Footage Indic...

Page 12: ...s screwdriver Removing the Rear Cover 1 Turn off the unit with the Power button 2 Unplug the unit from the power source and then remove the power cord from the back of the unit 3 Unscrew and remove th...

Page 13: ...bly 3 Remove the Front Grille carefully to ensure that the Ionization Needle in the top center of the front of the unit is not damaged 4 Clean the Front Grille using compressed air vacuum cleaner damp...

Page 14: ...ean the filter as described in the Routine Maintenance section on page 12 You can eliminate this message after cleaning by pressing the NORMAL HIGH button for 3 seconds Replace NCC Cell This message d...

Page 15: ...Technologies www resprtech com The Unit is Operating in High Mode or Away Mode but No Noticeable Purification is Being Produced 1 Ensure that the Purification Plate is clean See Step 4 2 The Purifica...

Page 16: ...side and slowly insert it into the Purification Plate Slot The Purification Plate Generates an Electrical Arc an Arcing Noise or a Burning Odor This means the Purification Plate is damaged and must be...

Page 17: ...purchase to your ReSPR distributor All transportation charges on parts or units submitted under this Warranty shall be borne by purchaser Unless this Warranty is expressly renewed or extended by ReSP...

Page 18: ...put 38VDC 3A See the power supply label for certifications and warnings PCO NCC Cell Normal Mode Output Purification Plate High Mode Output 25 360mg ozone per hour Ionization Needle 24 to 30 KV 20 30...

Page 19: ...19 www resprtech com ReSPR Technologies...

Reviews: