Control Panel

7

Positioning the Control Panel

When  choosing  a  suitable  location  for  the  Control

Panel, the following points should be considered.

1.

The Control Panel should be located in a position

out  of  sight  of  potential  intruders  and  in  a  safe

location, but easily accessible for system operation.

2.

The Control Panel should be mounted on a sound

flat surface to ensure that the rear tamper switch

on the Control Panel is closed when the Panel is

mounted.  The Control Panel should be mounted

at a convenient height of between 1.5 and 2m and

in a position where it will be seen each day.

Note: If  small  children  are  in  the  household,  a

further  consideration  should  be  given  to  keeping

the units out of their reach.

3.

It is recommended that the Control Panel should

be  positioned  such  that  the  Exit/Entry  tone

(emitted by the Control Panel) can be heard from

outside the property.

4.

The  Control  Panel  should  be  mounted  within  a

protected  area  so  that  any  intruder  cannot  reach

the  Control  Panel  without  opening  a  protected

door  or  passing  through  an  area  protected  by  a

PIR Detector when the system is armed.

5.

The Control Panel must be located within reach of

a mains socket.

6.

If the telephone voice dialler is to be used then the

Control Panel will need connecting to a convenient

telephone point.

7.

Do  not  locate  the  Control  Unit  closer  than  1m  to

any  large  metallic  object,  (e.g.  mirrors,  radiators,

etc)  as  this  may  affect  the  radio  range  of  the

Control Panel.

Installing the Control Panel

1.

Undo the two captive fixing screws on top of the

panel  and  open  the  cover.    The  cover  is  hinged

along the bottom edge.

2.

Unclip  and  remove  the  two  back-up  batteries  on

either side of the panel.

3.

Hold the Control Panel in position on the wall and

mark  the  positions  of  the  four  fixing  holes.

Remove the Panel and drill four 5mm holes and fit

the 25mm Wall Plugs.

Note: The wall plugs supplied with the product are

not suitable for plasterboard walls, if mounting the

Control  Panel  onto  plasterboard  use  proprietary

wall plugs.

Important: Do  not  drill  the  fixing  holes  with  the

Control Panel in position; as the resulting dust and

vibration may damage the Control Panel’s internal

components and invalidate the guarantee.

External view of Control Panel

1

2

3

4

5

6

FIRE

TAMPER

ZONE

1

2

3

4

5

6

8

7

0

ESC

9

Zone LEDs

Status LEDs

Keypad

Summary of Contents for SA3 E PLUS

Page 1: ...SA3 E PLUS 6 Zone Wirefree Alarm System with Voice Dialler Installation and Operating Instructions...

Page 2: ...the System 17 Initial Testing 17 Testing an Installed System 17 Detector Test 17 Hard Wired Solar Siren Test 18 Testing the System continued Solar Siren Test 18 Control Panel LED Test 18 Solar Siren...

Page 3: ...battery for PIR Movement Detectors x 5 3V CR2032 Lithium cells for Remote Control and Magnetic Contact Detectors Important Please check all items listed above are included in the package For system i...

Page 4: ...Delay Armed zones will not become fully armed until after the Exit delay period has expired When a Detector on a Delay Armed zone is triggered an alarm condition will not be triggered until after the...

Page 5: ...e planning to operate the Jamming Detection feature we recommend that you wait at least 30 days before activating this feature this will allow time for you to become familiar with the operation of you...

Page 6: ...curity requirements and plan your installation The alarm system may be extended at any time to provide even greater protection by fitting additional devices to meet your personal security needs Planni...

Page 7: ...cted by a PIR Detector when the system is armed 5 The Control Panel must be located within reach of a mains socket 6 If the telephone voice dialler is to be used then the Control Panel will need conne...

Page 8: ...attery terminal Blue lead to battery terminal Battery 2 right Blue lead to battery terminal Black lead to battery terminal Important Take care when connecting battery leads to the batteries as connect...

Page 9: ...etting The LEDs will switch to the opposite state each time the button is pressed LED ON 1 House Code DIP Switch On LED OFF 0 House Code DIP Switch Off b Press to save the new setting and return to pr...

Page 10: ...vision If movement is detected an alarm signal will be generated if the system and alarm zone is armed Note PIR Detectors will also detect animals so ensure that pets are not permitted access to areas...

Page 11: ...range of the Device Installing and configuring the PIR Movement Detectors Ensure that the Control Panel is in Test mode 1 Undo and remove the fixing screw from the bottom edge of the PIR Detector Care...

Page 12: ...ver Push the lower edge of the PIR Detector into place and refit the fixing screw in the bottom edge of the PIR Detector to secure in position Do not over tighten the fixing screws as this may damage...

Page 13: ...If an additional wired Magnetic Contact Detector is required this should be wired to the terminal block provided in the battery compartment The wired contact should be connected using two core 24AWG...

Page 14: ...ing provides full protection against adverse weather conditions An LED Strobe unit is built into the siren to act as a visible deterrent indication that the system is active The Strobe LEDs will slowl...

Page 15: ...6mm holes and fit the wall plugs 3 Fit the two 30mm fixing screws in the top holes leaving approx 10mm of the screw protruding 4 Fit the top keyhole slots of the mounting plate over the screw heads A...

Page 16: ...e rechargeable battery to the charging leads Connect the Red lead to the Red terminal and the Black lead to the Black terminals Note Once the batteries have been connected the Siren will be operationa...

Page 17: ...device is tested in turn as it is installed refer to testing instructions for particular device Testing an Installed System The Control Panel has a programmed test routine You may test the system at a...

Page 18: ...lled Press to exit voice dialer test Factory Defaults Reset Factory Default Conditions 1 Press to place the system in Test Mode 2 Undo the Control Panel cover fixing screws and open the cover 3 Switch...

Page 19: ...D OFF House Code DIP Switch Off Press to save the new setting and return to programming Press to return to programming mode without saving b Using a Remote Control With the required House Code already...

Page 20: ...imit of the external Siren expires whichever occurs first Part Arm Default setting Zone 1 Disabled Zones 2 6 Active Press The zone LEDs corresponding to the zones currently active during Part Arm mode...

Page 21: ...ll illuminate 0 2 seconds 1 30 seconds 2 1 minute 3 3 minutes 4 5 minutes 5 equal to Alarm Duration Press the key corresponding to the required Hardwired output activation period the corresponding zon...

Page 22: ...e in the number when dialed Press to save the new number and return to programming mode Press to return to programming mode without saving Alarm Message Play Time This is the total time for which the...

Page 23: ...he phone number The LED will toggle between states each time the button is pressed Press to save the new number and return to programming mode Press to return to programming mode without saving Call A...

Page 24: ...pires If the system has not been Disarmed when the Entry Delay expires a Full Alarm condition will be initiated If a Full Alarm condition occurs the appropriate zone LED that triggered the alarm will...

Page 25: ...ll be initiated even if the system is disarmed The alarm condition will continue either for the alarm duration when the system will automatically reset or until the system is Disarmed from the Remote...

Page 26: ...s covered with a light proof material to prevent it being energized Control Panel The rechargeable batteries have a typical life of 3 4 years and need no maintenance during this period provided they a...

Page 27: ...o your system and to assist Trouble Shooting Zone Settings You may make a note of your User Access Code and System House Code below User Access Code System House Code Use the above diagram to record y...

Page 28: ...the House Code is correctly set 2 Ensure Detector is within effective radio range of the Control Panel and equipment is not mounted close to metal objects 3 Detector battery low Replace Detector batte...

Page 29: ...ted a Ensure jumper link removed b Check that additional contact is correctly wired c Ensure that Magnet is correctly positioned in relation to Detector and that the gap between Magnet and Detector is...

Page 30: ...your statutory rights and is valid for UK and EIRE only If you believe the product to be faulty or in the unlikely event of the product developing a fault during the warranty period then please contac...

Page 31: ...Notes 31...

Page 32: ...peration time in complete darkness up to 25 days 95dB Piezo Siren 3 minute alarm duration limiter optional Auto reset Siren Disable selectable Dual front and rear anti tamper protection Jamming Detect...

Reviews: