Replay Alarm Message

The  recorded  alarm  message  may  be  replayed  and

listened  to  using  the  telephone  handset  of  a  phone

connected  to  another  extension  socket  on  the  same

phone line.

Press

The zone 1 LED will illuminate.

Pick up the telephone handset and press            to stop

the dialing tone.

Press              to  start  replaying  the  recorded  alarm

message.

Zone  LED  1  will  flash  while  the  alarm  message  is

being replayed.  At the end of the message the Control

Panel  will  beep  twice  and  return  to  programming

mode.  Alternatively press             to stop replaying the

message  before  the  end  and  return  to  programming

mode.

Call Routing

This controls which telephone numbers are enabled in

the  dialing  sequence  and  are  dialed  when  the  voice

dialler is activated.

Default setting:   all numbers inactive

Press

Zone  LEDs  1-4  will  be  illuminated  to  indicate  the

active status of telephone numbers 1-4 in the routing

sequence.  LEDs for telephone numbers disabled will

be OFF.

LED ON         Telephone number enabled

LED OFF        Telephone number disabled

To change the active status of a phone number press

the button corresponding to the phone number.  The

LED will toggle between states each time the button

is pressed.

Press                  to  save  the  new  number  and  return  to

programming mode.

Press             to return to programming mode without

saving.

Call Attempts

This is the total time for which the alarm messages will

be played & repeated when a call made by the voice

dialer is answered.

Default setting:   3

Press

The zone LED corresponding to the current setting will

illuminate.

Zone 1 LED        1 attempt

Zone 2 LED        2 attempts

Zone 3 LED        3 attempts

Zone 4 LED        4 attempts

Zone 5 LED        5 attempts

Press the key corresponding to the required number

of dialing attempts, the corresponding zone LED will

illuminate as the setting is changed.

Press                to  save  the  new  setting  and  return  to

programming mode.

Press             to return to programming mode without

saving.

Dial Method

This  enables  the  telephone  dialler  to  be  set  for  the

type of exchange it is connected to.

Default setting:   Tone/DTMF

Press

The zone LED corresponding to the current setting will

illuminate.

1          Tone/DTMF

2          Pulse

Press  the  key  corresponding  to  the  required  dial

method,  the  corresponding  zone  LED  will  illuminate

as the setting is changed.

Press                to  save  the  new  setting  and  return  to

programming mode.

Press             to return to programming mode without

saving.

23

3

2

5

2

6

2

4

2

ESC

ESC

ESC

ESC

Summary of Contents for SA3 E PLUS

Page 1: ...SA3 E PLUS 6 Zone Wirefree Alarm System with Voice Dialler Installation and Operating Instructions...

Page 2: ...the System 17 Initial Testing 17 Testing an Installed System 17 Detector Test 17 Hard Wired Solar Siren Test 18 Testing the System continued Solar Siren Test 18 Control Panel LED Test 18 Solar Siren...

Page 3: ...battery for PIR Movement Detectors x 5 3V CR2032 Lithium cells for Remote Control and Magnetic Contact Detectors Important Please check all items listed above are included in the package For system i...

Page 4: ...Delay Armed zones will not become fully armed until after the Exit delay period has expired When a Detector on a Delay Armed zone is triggered an alarm condition will not be triggered until after the...

Page 5: ...e planning to operate the Jamming Detection feature we recommend that you wait at least 30 days before activating this feature this will allow time for you to become familiar with the operation of you...

Page 6: ...curity requirements and plan your installation The alarm system may be extended at any time to provide even greater protection by fitting additional devices to meet your personal security needs Planni...

Page 7: ...cted by a PIR Detector when the system is armed 5 The Control Panel must be located within reach of a mains socket 6 If the telephone voice dialler is to be used then the Control Panel will need conne...

Page 8: ...attery terminal Blue lead to battery terminal Battery 2 right Blue lead to battery terminal Black lead to battery terminal Important Take care when connecting battery leads to the batteries as connect...

Page 9: ...etting The LEDs will switch to the opposite state each time the button is pressed LED ON 1 House Code DIP Switch On LED OFF 0 House Code DIP Switch Off b Press to save the new setting and return to pr...

Page 10: ...vision If movement is detected an alarm signal will be generated if the system and alarm zone is armed Note PIR Detectors will also detect animals so ensure that pets are not permitted access to areas...

Page 11: ...range of the Device Installing and configuring the PIR Movement Detectors Ensure that the Control Panel is in Test mode 1 Undo and remove the fixing screw from the bottom edge of the PIR Detector Care...

Page 12: ...ver Push the lower edge of the PIR Detector into place and refit the fixing screw in the bottom edge of the PIR Detector to secure in position Do not over tighten the fixing screws as this may damage...

Page 13: ...If an additional wired Magnetic Contact Detector is required this should be wired to the terminal block provided in the battery compartment The wired contact should be connected using two core 24AWG...

Page 14: ...ing provides full protection against adverse weather conditions An LED Strobe unit is built into the siren to act as a visible deterrent indication that the system is active The Strobe LEDs will slowl...

Page 15: ...6mm holes and fit the wall plugs 3 Fit the two 30mm fixing screws in the top holes leaving approx 10mm of the screw protruding 4 Fit the top keyhole slots of the mounting plate over the screw heads A...

Page 16: ...e rechargeable battery to the charging leads Connect the Red lead to the Red terminal and the Black lead to the Black terminals Note Once the batteries have been connected the Siren will be operationa...

Page 17: ...device is tested in turn as it is installed refer to testing instructions for particular device Testing an Installed System The Control Panel has a programmed test routine You may test the system at a...

Page 18: ...lled Press to exit voice dialer test Factory Defaults Reset Factory Default Conditions 1 Press to place the system in Test Mode 2 Undo the Control Panel cover fixing screws and open the cover 3 Switch...

Page 19: ...D OFF House Code DIP Switch Off Press to save the new setting and return to programming Press to return to programming mode without saving b Using a Remote Control With the required House Code already...

Page 20: ...imit of the external Siren expires whichever occurs first Part Arm Default setting Zone 1 Disabled Zones 2 6 Active Press The zone LEDs corresponding to the zones currently active during Part Arm mode...

Page 21: ...ll illuminate 0 2 seconds 1 30 seconds 2 1 minute 3 3 minutes 4 5 minutes 5 equal to Alarm Duration Press the key corresponding to the required Hardwired output activation period the corresponding zon...

Page 22: ...e in the number when dialed Press to save the new number and return to programming mode Press to return to programming mode without saving Alarm Message Play Time This is the total time for which the...

Page 23: ...he phone number The LED will toggle between states each time the button is pressed Press to save the new number and return to programming mode Press to return to programming mode without saving Call A...

Page 24: ...pires If the system has not been Disarmed when the Entry Delay expires a Full Alarm condition will be initiated If a Full Alarm condition occurs the appropriate zone LED that triggered the alarm will...

Page 25: ...ll be initiated even if the system is disarmed The alarm condition will continue either for the alarm duration when the system will automatically reset or until the system is Disarmed from the Remote...

Page 26: ...s covered with a light proof material to prevent it being energized Control Panel The rechargeable batteries have a typical life of 3 4 years and need no maintenance during this period provided they a...

Page 27: ...o your system and to assist Trouble Shooting Zone Settings You may make a note of your User Access Code and System House Code below User Access Code System House Code Use the above diagram to record y...

Page 28: ...the House Code is correctly set 2 Ensure Detector is within effective radio range of the Control Panel and equipment is not mounted close to metal objects 3 Detector battery low Replace Detector batte...

Page 29: ...ted a Ensure jumper link removed b Check that additional contact is correctly wired c Ensure that Magnet is correctly positioned in relation to Detector and that the gap between Magnet and Detector is...

Page 30: ...your statutory rights and is valid for UK and EIRE only If you believe the product to be faulty or in the unlikely event of the product developing a fault during the warranty period then please contac...

Page 31: ...Notes 31...

Page 32: ...peration time in complete darkness up to 25 days 95dB Piezo Siren 3 minute alarm duration limiter optional Auto reset Siren Disable selectable Dual front and rear anti tamper protection Jamming Detect...

Reviews: