29
PIR Movement Detector not detecting a
person’s movement
1. Check battery connections are good.
2. Sensitivity detection set too low – reset to high
sensitivity detection.
3. Check that the Detector is correctly set up.
4. Ensure DIP switches 1- 3 of SW3 are correctly set.
5. Ensure that Detector is mounted the correct way
up, (i.e. with detection window at the bottom).
6. Ensure that the Detector is mounted at the correct
height, (i.e. 2-2.5m).
7. Allow up to three minutes for Detector to stabilize.
8. Ensure Detector is within effective radio range of
Control Panel and is not mounted close to metal
objects which may interfere with RF transmission.
PIR Movement Detector LED flashes on
detection of movement, (device in normal
operation mode)
1. Low battery – replace battery.
Magnetic Contact Detector not working
1. Ensure batteries are connected with correct polarity.
2. Ensure battery connections are good.
3. Ensure ‘House Code’ is correctly set.
4. Ensure DIP switches 9, 10 and 11 are set correctly.
5. Ensure Detector is within effective radio range of
Control Panel and is not mounted close to metal
objects which may interfere with RF transmission.
6. If an additional Magnetic Contact Detector is not
connected ensure jumper link fitted
7. If additional Magnetic Contact Detector is
connected:
a. Ensure jumper link removed.
b. Check that additional contact is correctly wired.
c. Ensure that Magnet is correctly positioned in
relation to Detector and that the gap between
Magnet and Detector is not too large.
Note: If an additional contact is used then the
doors / windows protected by both the main
wirefree Detector and the additional wired
Detector must be closed when either is opened.
If one of the doors/windows is already open then
the opening of the other door/window will not be
detected.
Magnetic Contact Detector false alarming
1. Ensure that magnet is correctly positioned in
relation to Detector.
2. Ensure that gap between magnet and Detector
is less than 10mm.
3. Tamper switch below battery cover not depressed
– check battery cover is fitted correctly and that
fixing lugs are not broken.
LED on Magnetic Contact Detector illuminating
when door or window is opened
1. Low battery – replace batteries.
Voice Dialler not operating
1. Check that phone line is operating normally by
connecting a normal telephone to the socket that
the Control Panel is plugged into and check for a
dialing tone.
2. Check Control Panel is connected to telephone
socket using lead supplied.
3. Voice dialer not configured correctly:
a. Phone number(s) incorrectly programmed.
b. Phone number(s) not enabled in Call Routing
sequence.
c. Alarm Message has not been recorded.
d. Dial method incorrectly set for type of
exchange, (i.e. Tone/DTMF or Pulse).
Symptom
/
Recommendation
Symptom
/
Recommendation