R8845U UNIVERSAL SWITCHING RELAY

68-0215—02

4

Fig. 2. R8845U Internal schematic and typical hookup.

Fig. 3. R8845U schematic diagram for multizone, hydronic 

heating system (applies for any number of additional zones).

Fig. 4. R8845U hookup for L7124A/L8124A in an oil-fired, tankless hot water, zoned, pump system.

L1
HOT

L2

R(T) W(T)

C

L2

L1

N.O.

COM

1

1

TO
POWER

LOW VOLTAGE (CLASS 2)
2-WIRE THERMOSTAT

CALL FOR HEAT LED

POWER SUPPLY. PROVIDE OVERLOAD PROTECTION 
AND DISCONNECT MEANS AS REQUIRED.

M14294

B

A

X2

X1

LOAD 1

RELAY

LED

TO
POWER

LOAD 2

LOW-VOLTAGE
POWERPILE®

1

1

G

AUTOMOTIVE
FUSE

L1
HOT

L2

2

L

W(T)

L

R(T)

1

B

A

1

1

R8845U RELAY

POWER SUPPLY.  PROVIDE OVERLOAD PROTECTION 
AND DISCONNECT MEANS AS REQUIRED.

IF CONTROLLING TWO LOADS, USE:
     N.O. AND COM FOR LINE VOLTAGE LOAD,
     A AND B FOR LINE OR LOW VOLTAGE LOAD.

IF USING LOW VOLTAGE, USE A SEPARATE TRANSFORMER.

M14296

T

T

THERMOSTAT

ZONE 1

ZC

ZP

B1

B2

C1

C2

1

2

BURNER

CIRC.

LINE

THERM.

BURNER

CONTROL

CIRCULATOR

ZONE 1

2

3

THERMOSTAT

ZONE 2

CIRCULATOR

ZONE 2

TO ADDITIONAL R8845U 

RELAYS FOR OTHER ZONES

HYDRONIC HEATING

CONTROL TERMINALS

2

3

N.O.

COM

L1
(HOT)

L2

1

2

3

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.

CONTROL CASE MUST BE CONNECTED TO EARTH GROUND. USE GROUNDING SCREW PROVIDED.

B1 IS 1/4 IN. TAB TERMINAL.

L2

L1 C1 C2 B2

ZR

ZC

B1

M14298

3

2

BURNER
AND
IGNITION

L7124A, L8124A

G

T

T

F

F

T87F

N.O.

B

A

COM

L2

L1

W(T)

R(T)

N.O.

B

A

COM

L2

L1

W(T)

R(T)

T87F

R8845U RELAY

R8184

T87F

R8845U RELAY

PUMP

PUMP

PUMP

BLACK

WHITE

ORANGE

C554

1

W(T)

R(T)

Summary of Contents for R8845U

Page 1: ...s unit may not exactly match the listed spec ifications Also this product is tested and calibrated under closely controlled conditions and some minor differences in performance can be expected if thos...

Page 2: ...onnections R8845U has lower output load rating Check load requirements use RA889A if normally closed contacts are required R182B 1 3 6 8 R182C 1 2 6 8 3 5 R182J L1 L2 4 7 If used to replace an R182J i...

Page 3: ...er right corner for the keyhole type mounting hole Screw it down within about 1 8 in 3 mm of the surface 3 Hang the relay on the screw position the case and start the bottom screw 4 Tighten both screw...

Page 4: ...PROTECTION AND DISCONNECT MEANS AS REQUIRED IF CONTROLLING TWO LOADS USE N O AND COM FOR LINE VOLTAGE LOAD A AND B FOR LINE OR LOW VOLTAGE LOAD IF USING LOW VOLTAGE USE A SEPARATE TRANSFORMER M14296 T...

Page 5: ...OL CASE MUST BE CONNECTED TO EARTH GROUND USE GROUNDING SCREW PROVIDED B1 IS 1 4 IN TAB TERMINAL 1 2 L7148A L8148A 2 1 M14300 3 3 X2 X1 N O COM L2 L1 W T R T X2 X1 N O COM L2 L1 W T R T X2 X1 N O COM...

Page 6: ...CASE MUST BE CONNECTED TO EARTH GROUND USE GROUNDING SCREW PROVIDED 1 1 20 VA M13315 R8888 1 G R8845U R T W T TO APPROPRIATE CONNECTIONS AS REQUIRED BY THE SYSTEM H1 H2 TYPICALLY CONNECTED TO T T OF...

Page 7: ...ake certain the relay controls the equipment as intended TROUBLESHOOTING Test Button This connection is the same as a call for heat connection between the R T and W T terminals Heat Call LED The LED s...

Reviews: