57
Updating DSP Firmware
The latest DSP firmware files (.bin files) were installed in your array before it was shipped to you. These files contain the loudspeaker
specific EQ, crossover and protection settings for the loudspeaker and are updated from time to time as the firmware is improved.
If you haven’t already done so, make sure you have the latest DSP firmware files (.bin files). Be aware that .bin files names which start
with RH4... are 48 kHz files; 96 kHz files start with RH9... You’ll find them on the RHAON download page below the Program download.
Also notice that some files end with the suffix “v1.xx” and others with the suffix “v2.xx”. Do not attempt to use v2.xx files to update arrays
having v1.xx files or v1.xx files to update arrays running v2.xx files.
Updated files need to be placed in the “DSP_Firmware” sub folder of your RHAON installation (typically “C:\Program Files\Renkus-
Heinz\RHAON\DSP_Firmware”).
Step 1:
In RHAON, right-click on the one of the loudspeaker listings in the directory tree view or on the loudspeakers icon in the main
display area and select “Update DSP Firmware…”. The pop up screens are the same ones we explored on page 55 under Updating
Microcontroller Firmware.
Selecting Update DSP Firmware will open the window shown below. Notice that the program lets you know what firmware is installed in
the loudspeaker.
Note: If you are installing the DSP Firmware into a multiple module array, the firmware needs to be installed individually into each of the
array modules. We’ll start with the Master module.
Users Manual
IC-R