To connect an IC-R array to the RHAON network, you first make the hardware connections, and then (if you are using CobraNet for
digital audio distribution) assign signal routing using RHAON software. Since all Ethernet connections are made using RJ45 connectors
and Cat 5e cable, the network infrastructure is cost-effective and easy to install. You can also connect Serial Digital (AES3id aka
AES/EBU) and analog audio to an IC-R, as well as Fault Detect and Fault Relay lines.
Appendix III: ICONYX-R Hardware Inputs, Outputs & Indicators, Dimensions
Primary & Secondary Ethernet Inputs
RJ-45 female;when both are connected,
changeover to Secondary is automatic if
Primary fails. Yellow LED flashes when the
connector is active, glows steadily when
data is streaming. Green LEDs glow when
connected but inactive, turn Orange to indi-
cate a faulty connection.
Primary Analog Input/Output
XLR female; pin 1 chassis, pin 2 +, pin 3 -
Looping AES/EBU Input and Looping
Output
Secondary Analog Input/Output
Can be configured for “priority override”
Fault Input
Opto-isolated input used to monitor the pres-
ence of an external wiring loop; absence of a
voltage is reported to the DSP and transmit-
ted to the monitoring computer over the
Ethernet. Operates on 5 to 24 V DT
Fault Relay
NO / NC relay contacts used to report a fail-
ure to an external monitoring system; used
mainly to trigger a failure indication on a
hard-wired monitoring device; handles up to
0.5 Amps at 24 V AC or DC.
Signal LED
Flickers when an audio signal of at least -30
dBu is present at the primary analog audio
input.
Power LED
Glows when amplifier is On (not in Standby)
Overdrive LED
Flashes red when the Primary Analog Input
preamplifier is being overdriven
Thermal LED
Lights to indicate that an over-temperature
sensor has shut down the amplifier
Input Pad & LED Indicator
On / Off 10 dB pad for Primary Analog Input;
allows input signals of up to +24 dBu when
inserted.
Push Button Volume Controls
Also function as a manual Standby/On
control
Mute Button
Push-To-Reset
Circuit Breaker
NOTE:
1.To prevent inadvertent operation the Mute, Volume Up & Volume Down, Input Pad and AES/EBU push buttons need to be pressed and held down
for several seconds before they activate.
2. In multi-module arrays, AC power for the array can be brought into any of the input ports; Signal cables must terminate in the input port of the des-
ignated “Master” module.
100/240 V AC
Power Connector
Master/Slave Setup Switches
Preset Controls & Readout
Remote Preset Control Connections
for remote control of preset selection from
RS485 devices and rotary switches.
AES/EBU Input Switch
When On, turns analog input 1 into an
AES/EBU input.
Fault Input
See below for details
Fault Relay
See below for details
50
Users Manual
IC-R