INSTALLATION
General Information

Iconyx Gen 5 was designed to be easy to install on either a flat surface, such as a wall, or suspended from a ceiling. For installation in a recess or 
wall or in an alcove, see our application note on flush mounting. The amplifiers are convection cooled and their heat sinks require at least an inch 
(25 mm) of separation from the nearest surface.
The included hinge kits allow wall mounted arrays to be rotated 90 degrees away from the wall to provide easy access to the rear ports during 
installation and for any testing or service. They also provide the separation needed for cooling.
The actual installation should be made either by, or under the close supervision of, someone experienced in installation techniques, and rigging 
related to the type of mounting surface or wall.

Wall Mounting Information

The following instructions assume that the array(s) will be mounted using the included HK series hinge kits.
HK series hinge kits come standard with Gen 5 arrays and will be packed in one of the cartons. Each mounting plate has a pin that may be moved 
to provide for either “right” or “left” swing away from the wall. IC8-RN columns will have two hinge sections; all others will have three hinge 
sections.
The female hinges are attached to the column and the male hinges to the wall. The photos below show the male mounting plates with pins in 
both positions for illustrative purposes.
Notice that one of the wall mounting hinge plates has a metal strap attached to it. This hinge plate can go on the top or bottom. The metal strap 
attaches to the top or bottom of the array after it is hung and is used to lock the column array in place.

Hint: To simplify the mounting many installers will first cut a “backing plate” the size of the column out of heavy 

plywood and mount the hinge plates on it. It’s a lot easier to align the hinge sections on a piece of plywood than 
it is on the wall. Then, when the alignment is perfect they mount the “backing plate” to the wall. After that, it’s 
usually a comparatively easy task to hang the column array on the backing plate.

After the column array is hung on the wall, remove the machine screw from the center of the end cap at the end with the restraining strap and 
use it to attach the strap.
In outdoor or weatherized applications, if the restraining strap is used at the top, it must be sealed with silicone caulk to prevent water ingress.

Summary of Contents for ICONYX IC16-8-RD

Page 1: ...e Line Array Loudspeaker Systems ICONYX Gen5 USERS MANUAL Assembly Installation Instructions IC8 RN IC8 RD IC16 8 RN IC16 8 RD IC16 RN IC16 RD IC24 16 RN IC24 16 RD IC24 RN IC24 RD IC32 24 RN IC32 24...

Page 2: ...nings servicing instructions are for use by qualified personnel only To avoid electric shock do not perform any servicing other than that contained in the Ope ration Instructions unless you are qualif...

Page 3: ...E INTRODUCTION 4 ASSEMBLY INSTRUCTIONS 5 INSTALLATION 8 HARDWARE CONNECTIONS INDICATORS 11 FERRITE CLAMP INSTALLATION 12 NETWORK CONNECTIONS 13 DANTE NETWORKING 13 FAULT RELAY FAULT LED 14 SERVICING A...

Page 4: ...about Renkus Heinz loudspeakers or encounter a problem designing installing setting up or operating a Renkus Heinz system please call our technical support staff at 1 949 588 9997 and ask the operato...

Page 5: ...es or in an array of all Master devices As a Master Aux device the module with the Ethernet and audio connections is the Master and all the other modules are Auxes controlled by the Master module In a...

Page 6: ...the eight 3 Phillips machine screws from each side of the cabinet and lift the end cap and its mounting brackets out of the cabinet It may be necessary to loosen the top hex bolts 7 Use the same eigh...

Page 7: ...her modules will be Aux IDs 1 2 3 in ascending order However the modules can be put in any order For example the Master may be installed on top to allow for a cable drop near the top of the array The...

Page 8: ...de for either right or left swing away from the wall IC8 RN columns will have two hinge sections all others will have three hinge sections The female hinges are attached to the column and the male hin...

Page 9: ...been evaluated for safety requirements using other mounting kits Renkus Heinz is not responsible for the quality or effectiveness of an installer s mounting of this heavy load to the wall type encoun...

Page 10: ...re installed 6 NOTE The male mounting plate with an attached slotted locking strap can go in the top or bottom location The components of the mounting plate must be rearranged to fit when used in the...

Page 11: ...ent at the primary analog audio input Aux Setup DIP Switches and Legend Analog Inputs 2 and 1 Phoenix 6 pin connector AES EBU Input Reset Button When pressed and held for three seconds the loudspeaker...

Page 12: ...or audio cables and a large clamp for the power cable insert two runs of the loop into the clamp The clamp on the audio cable should be approximately 3 inches 80mm from the connector Pic 2 3 Press the...

Page 13: ...rray is a node on the network and connects to the network switch via a home run CAT5e or CAT6 Ethernet cable The maximum cable run supported on copper Ethernet is 100 meters Gen5 RD units are availabl...

Page 14: ...ed in the field by qualified personnel without being removed from its mounting position The transducers can be replaced from the front of the column by removing the grille to expose the transducers an...

Page 15: ...sducers making it difficult to determine if a certain transducer has failed or is just being driven at a much lower level than other transducers No movement of the cone of a transducer is not positive...

Page 16: ...19201 Cook Street Foothill Ranch CA 92610 USA Phone 1 949 588 9997 Fax 1 949 588 9514 sales renkus heinz com www renkus heinz com RH 808 Rev C September 2020...

Reviews: