background image

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data 

processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent 

the technical status at the time of printing.  
© Copyright 2014 by Conrad Electronic SE. 

Before you put device into operation

Put the fountain pump into a shallow pond or a similar place and switch on. Through various nose 

pieces, the pumped water is sprayed out in different patterns. 
For operation, the fountain pump should be submerged in water at 30 - 40 cm depth, so that the 

extension tube and a selected nose piece would rise over the water level.

   At that, do not put the pump into bottom sludge, but use some slightly raised platform.

Using the T-socket supplied with the device you can attach (if desired) another nose piece or a 

hose e.g. for watering the garden.

   Never block both shutoff valves of the T-socket, otherwise the fountain pump can be 

damaged!

A grip on the top enables to fasten the fountain pump additionally with a rope.

   Never hold or fasten the fountain pump by the mains cabel or the hose; only the grip on 

the top can be used for this purpose.

 

The fountain pump can only be operated in the upright position!

The pumped water should be clean and clear. Only fine suspended matter is admissible, which may 

occur in every normal garden pond. Otherwise the nose pieces will be occluded!
Coarser impurities (leaves, dirt particles, pebbles etc.) occlude the suction ports; furthermore, they 

block the pump.

Getting started

Insert the mains plug of the fountain pump to a mains socket. 
The fountain pump starts immediately and begins pumping water. 
If the water is not pumped, it can be indicative of air in the pump. Wait for few seconds or remove 

and insert the plug briefly from the mains socket for several times.

Removing from service

Should the fountain pump be taken out of service (e.g. for cleaning, maintenance or storage in 

winter), then proceed as follows:
•   Disconnect  the  fountain  pump  from  the  power  supply,  pull  the  mains  plug  out  of  the  mains  

socket.

•   Take  the  fountain  pump  out  of  the  water  using  the  carrier  handle  (or  the  fastening  rope  

attached).

   Never lift the fountain pump using the hose or the mains cord! Otherwise the power 

cord may get damaged, risk of an electric shock!

•   If a hose is mounted to the fountain pump (e.g. via the T-socket), then disconnect it from the 

fountain pump.

•   Let the residual water drain out of the fountain pump holding it slantwise. 
•   Dry up the fountain pump and the power cord. If required, clean its outer surface and filter. Wind 

up the mains cable.

•  In winter, keep the water pump in a dry space protected against frost.

   Also do not forget to empty the hoses laid outdoor to avoid frost damages; open water 

taps if available.

•   Only the carrying handle can be used to carry the fountain pump. Never hold it using the hose or 

the mains cord.

•   A small quantity of water remains in the fountain pump after use or after the emptying operation. 

Therefore, when storing or transporting the pump in a vehicle, use an appropriate mat.

Maintenance and cleaning

Before cleaning disconnect the fountain pump from the mains; remove the mains plug from the 

power socket.
Use a soft clean cloth to clean the outer surfaces of the fountain pump. If necessary rinse the outer 

surface with clear water. 
The lower part of the filter can be removed from the fountain pump to facilitate cleaning of the 

filter and interior parts of the pump. Only clean running water can be used for this purpose. Turn 

the fountain pump upside down. Holding the housing firmly, turn the lower part in an anticlockwise 

motion a little to the left (1).
You can also remove the impeller. To do that, remove the single screw (2). At that, before you take 

out the impeller, you have to overcome certain resistance due to magnetic force (3).
After cleaning reassamble the fountain pump completely and properly.
Before putting in storage, dry up the fountain pump and the power cord.

    Never  use  abrasive  cleaning  agents,  cleaning  alcohol  or  other  chemical  solutions, 

since these can damage the housing or even impair functionality. 

Disposal

 

 Dispose of the unserviceable product according to the relevant statutory regulations!

Technical data

Operating voltage............................... 230 V/AC, 50 Hz
Protection class ................................. I
Protection type ................................... IPX8
Nominal output ................................... 38 W
Connection cable ............................... H05RN-F, 3 x 0,75 mm², length app. 10 m  
Delivery lift .......................................... max. 1,9 m above the intake port
Depth of immersion ........................... max. 3 m
Flow rate .............................................. up to 1400 l/h
Temperature of water ........................ max. +35 °C
Hose diameter .................................... 15 mm (1/2”)
Dimensions.......................................... 115 x 190 mm (Ø x H)

...............................................................

(max. height with extension tube and spraying nozzle 470 mm)

Weight .................................................. app. 1,9 kg (without extension tube/spraying nozzle)

Summary of Contents for 1275340

Page 1: ...mmischlauchleitungen mit Kurzzeichen H05RN F nach DIN VDE0620 Verwenden Sie ausschließlich Verlängerungsleitungen mit Schutzkontakt die für den Außenbereich geeignet sind Schützen Sie die Netzleitung vor Hitze Öl Benzin und scharfen Kanten treten Sie nicht auf die Netzleitung befahren Sie sie nicht z B Gartenkarre Fahrrad Auto Knicken Sie die Netzleitung niemals stellen Sie keine Gegenstände darau...

Page 2: ...npumpe darf niemals über das Netzkabel oder den Schlauch heraus gezogen werden Dabei kann das Netzkabel beschädigt werden es besteht Lebensge fahr durch einen elektrischen Schlag Falls ein Schlauch an der Springbrunnenpumpe montiert ist z B über das T Stück so trennen Sie ihn von der Springbrunnenpumpe ab Lassen Sie Restwasser aus der Springbrunnenpumpe herauslaufen indem Sie sie schräg halten Tro...

Page 3: ...teel Item no 1275340 Intended use The fountain pump is designed for private use e g in hobby gardening The product is not intended for irrigation or irrigation systems in the industry production or public sectors e g garden com plexes Through various interchangeable nosepieces the water delivered by the fountain pump is sprayed out in an optically appealing manner As a pumped fluid only clear wate...

Page 4: ...pe attached Never lift the fountain pump using the hose or the mains cord Otherwise the power cord may get damaged risk of an electric shock If a hose is mounted to the fountain pump e g via the T socket then disconnect it from the fountain pump Let the residual water drain out of the fountain pump holding it slantwise Dry up the fountain pump and the power cord If required clean its outer surface...

Page 5: ... niveau d eau des capteurs des appareils d alarme etc Lorsque l appareil est transporté d un local froid vers un local chaud par ex lors du transport il peut s y former de la condensation Il y a alors danger de mort par électrocution Laissez le produit éteint atteindre la température ambiante avant de le remettre en service ou de le connecter à la tension du réseau Selon les cas cela peut prendre ...

Page 6: ...tion ou le tuyau Le cordon d alimentation pourrait en être endommagé dans ce cas il y a un danger d électrocution Si un tuyau est installé sur la pompe pour fontaine par ex avec le raccord en T il faut le décon necter de la pompe pour fontaine Laissez l eau restante s écouler de la pompe pour fontaine en la maintenant penchée Laissez sécher la pompe pour fontaine et le cordon d alimentation Si néc...

Page 7: ...nning verbindt Dit kan onder bepaalde omstandigheden enkele uren duren Gebruik het product alleen in een gematigd klimaat niet in een tropisch klimaat Laat verpakkingmateriaal niet achteloos liggen dit kan voor kinderen gevaarlijk speelgoed zijn O Gebruiksaanwijzing Fonteinpomp roestvast staal Bestelnr 1275340 Beoogd gebruik De fonteinpomp is bedoeld voor privé gebruik bijvoorbeeld in een hobbytui...

Page 8: ...ater Haal de fonteinpomp nimmer aan de netkabel of via de slang uit het water Daarbij kan de netkabel beschadigd raken er bestaat levensgevaar door een elektrische schok In het geval er een slang op de fonteinpomp is gemonteerd bijvoorbeeld via het T stuk dan ontkoppelt u deze van de fonteinpomp Laat achtergebleven water uit de fonteinpomp lopen door deze scheef te houden Droog fonteinpomp en netk...

Reviews: