Maintenance
WARNING:
Maintenance should only be carried out after the machine has been isolated from the electrical supply, compressed air
supply , or other energy sources in accordance with the machine manufacturer's instructions.
Periodically, check the security of mounting screws and electrical connectors.
Periodical electrical safety checks should include inspecting the mains cable for damage and safe connections. An earth continuity (ground
bonding) test may be applied between the protective earth pin of the mains connector and the metal case at a test current of no greater than
25 A.
Periodical safety checks should also include the function of the emergency stop system, including operation of all switches integrated into the
system. After operating the emergency stop system, the servo amplifier system should be checked to ensure servo power can be engaged.
Remove dust from the external surfaces with a clean dry cloth as the unit is not sealed against fluids/water.
UCC2 and UCC2-2 installation guide
www.renishaw.com
Issued 07 2021
59